Download Print this page

Heat Controller Geothermal Installation Instructions Manual page 28

Geothermal heat pump systems

Advertisement

Heat Controller, Inc.
Heat Controller, Inc.
Heat Controller GeoMax 2
Dimensions – Vertical Downflow
Vertical
Downflow
Model
in
024
026
cm
in
036
038
cm
in
048
049
cm
in
060
064
cm
in
070
072
cm
Blower
O
Opening
Front
Q
Air Coil Side
B
Right Return Discharge
Floor Foot Print
Filter Rack Dimensions
ASP
U
U
T
T
R
Front
Note: Filter Rack extends
out from cabinet 2.75Ó
S
Right Return Right View
- Filter Rack Knife Edge
ClimateMaster Geothermal Heat Pump Systems
HTV/HTD/HTH SERIES
HTV/HTH/HTD SERIES
Two Stage Geothermal Heat Pump Systems
Two Stage Geothermal Heat Pump Systems
Dimensions — Vertical Downflow Tranquility 27™
Discharge Connection
Duct Flange Installed (+/- 0.10 in, +/- 2.5mm)
M
O
Left
N
Supply
Return
Width
6.1
6.7
8.4
9.9
8.2
10.4
15.4
20.8
26.4
17.1
21.4
25.3
7.4
9.0
13.1
7.4
8.6
13.6
18.3
22.1
34.4
18.7
22.9
33.3
7.4
7.4
9.0
8.6
13.6
13.1
34.4
18.3
22.1
18.7
22.9
33.3
7.4
9.0
13.1
7.4
8.6
13.6
18.3
22.1
34.4
18.7
22.9
33.3
7.4
7.4
9.0
8.6
13.1
13.6
18.3
22.1
34.4
18.7
22.9
33.3
CAP=Control Access Panel
CSP=Compressor Service Panel
BSP=Blower Service Panel
ASP=Alternate Service Panel
P
N
N
A
A
Left Return Discharge
Left Return
3/4Ó HV
"
U
Knockout
1/2Ó LV
"
Knockout
C
Air Coil
C
T
S
Back
Back
2"
R
R
M
N
Left Return Left View
- Filter Rack Knife Edge
Discharge Dimensions
All Products Technical Guide: 2008 - 2009
Geothermal Heat Pump Systems
n
P
Q
Supply
Right
R
Depth
Return
9.1
10.9
10.8
1.7
9.4
1.8
27.9
23.5
4.6
23.0
27.4
4.2
12.9
10.4
1.7
13.3
10.5
1.5
33.7
27.5
3.8
32.7
26.5
4.2
12.9
13.3
10.4
1.7
10.5
1.5
33.7
27.5
3.8
32.7
26.5
4.2
12.9
10.4
1.7
13.3
10.5
1.5
33.7
27.5
3.8
32.7
26.5
4.2
13.3
12.9
10.5
10.4
1.7
1.5
33.7
27.5
3.8
32.7
26.5
4.2
Legend
P
2' [61cm] Optional Service
Blower
O
Access Right Rtn
Opening
(left opposite)
Front
M
Air Coil Side
2' [61cm] Service
B
Floor Foot Print
Power Supply
3 / 4" [19.1mm]
1.1 [27.9mm]
HV Knockout
1 / 2" [12.7mm]
Knockout
G F
Power Supply
Low Voltage
4
1 / 2" [12.7mm]
External Pump
CSP
L K
3
E
LV Knockout
J
Low Voltage
D
2
1
Aux Htr Knock-Out
Air Coil
Access Panels
Access Panels
Condensate
3 / 4" Glue
H
5
Front
S
O
P
9
10
26
Engineering Design Guide
Return Connection
Standard Deluxe Filter Rack
(+/- 0.10 in, +/- 2.5mm)
S
T
Return
Return
Depth
Height
22.2
26.2
26.2
21.2
22.3
21.1
66.5
56.6
53.6
56.4
66.4
53.9
27.1
26.1
23.2
27.8
23.1
26.2
70.6
66.5
58.4
68.9
66.4
59.0
27.1
30.1
30.2
23.2
27.8
23.1
76.7
70.6
58.4
68.9
76.5
59.0
27.8
27.1
34.1
23.2
26.2
23.1
70.6
66.5
58.4
68.9
86.7
59.0
27.1
34.1
23.2
23.1
27.8
34.2
58.4
70.6
86.9
68.9
86.7
59.0
Deluxe Filter Bracket
CSP
CAP
ASP
BSP
Condensate 3/4"
Glue
Access
Isometric View
1.6 [40.6mm]
Right Return
B
L
K
4
J
3
"
3/4Ó HV
2
CAP
Knockout
CSP
1/2Ó LV
"
1
Knockout
BSP
Condensate
3 / 4" Glue
(Left Return)
(Right Return)
Condensate 3/4Ó
"
glue socket
5
5
H
Front-View
O
P
N
Discharge Dimensions
Submittal Data
U
ASP
1.6 [40.6mm]
A
G
F
E
D
Q
Rev.: 7/26/04D
TT
27

Advertisement

loading