Heat Controller Geothermal Installation Instructions Manual page 12

Geothermal heat pump systems

Advertisement

Heat Controller, Inc.
Engineering Design Guide
Geothermal Heat Pump Systems
PERFORMANCE DATA
HTV036 & HTD036 Part Load
HT036 Part Load
HTV036, HTD036 & HTH036 Part Load
800 CFM Rated Airflow
EWT °F
GPM
20
8.0
4.0
30
6.0
8.0
4.0
40
6.0
8.0
4.0
50
6.0
8.0
4.0
60
6.0
8.0
4.0
70
6.0
8.0
4.0
80
6.0
8.0
4.0
90
6.0
8.0
4.0
100
6.0
8.0
4.0
110
6.0
8.0
4.0
120
6.0
8.0
†ARI/ASHRAE/ISO 13256-1 (WLHP applications) certified conditions are 86°F EWT, 80.6°F DB / 66.2°F WB
EAT in cooling and 68°F DB / 59°F WB EAT in heating.
Interpoaltion is permissable, extrapolation is not.
All entering air conditions are 80°F DB and 67°F WB in cooling and 70°F DB in heating
All performance data is based upon the lower voltage of dual voltage rated units
See performance correction tables for operating conditions other than those listed above.
Operation below 60°F EWT requires optional insulated water circuit.
Operation below 40°F EWT is based upon 15% antifreeze solution.
HTV/HTH/HTD SERIES
HTV/HTD/HTH SERIES
Heat Controller • Geothermal Heat Pump Systems
Two Stage Geothermal Heat Pump Systems
WPD
COOLING - EAT 80°F DB / 67°F WB
Sens/Tot
PSI
FT
TC
SC
Operation Not Recommended
4.7
10.9
1.2
2.8
29.8
18.9
2.6
6.1
30.1
18.9
4.5
10.4
30.3
19.0
1.1
2.5
30.6
20.4
2.6
5.9
30.8
20.4
4.4
10.2
31.0
20.5
1.0
2.2
30.3
21.1
2.5
5.7
30.7
21.2
4.2
9.7
30.9
21.2
0.9
2.0
29.2
21.2
2.4
5.5
29.9
21.3
4.1
9.5
30.2
21.4
0.8
1.8
27.7
20.6
2.3
5.3
28.6
20.9
4.0
9.2
29.0
21.1
0.7
1.7
26.0
19.8
2.3
5.2
26.9
20.2
3.9
9.0
27.4
20.4
0.6
1.5
24.2
19.0
2.1
4.9
25.1
19.4
3.7
8.5
25.6
19.6
0.6
1.4
22.7
18.5
2.1
4.8
23.4
18.7
3.6
8.3
23.8
18.9
0.6
1.3
21.5
18.3
2.0
4.6
22.0
18.3
3.4
7.9
22.3
18.4
0.5
1.2
20.7
18.0
1.9
4.5
21.1
18.3
3.3
7.7
21.3
18.4
n
KW
HR
EER
HWG
Ratio
0.5
0.63
0.79
32.5
37.7
0.63
0.75
32.7
40.3
0.5
0.4
0.63
0.73
32.8
41.6
0.67
0.90
33.6
34.0
0.8
0.66
0.84
33.7
36.9
0.7
0.7
0.66
0.81
33.7
38.3
1.2
0.70
1.03
33.8
29.4
0.8
0.69
0.95
33.9
32.2
1.1
0.7
1.0
0.69
0.92
34.0
33.7
0.7
0.72
1.19
33.3
24.6
1.3
2.5
2.2
0.71
1.09
33.7
27.3
1.2
0.71
1.05
33.8
28.7
1.1
2.0
0.74
1.36
32.3
20.4
2.2
1.8
2.0
0.73
1.26
32.9
22.7
1.7
0.73
1.21
33.1
24.0
1.8
1.5
0.76
1.56
31.3
16.7
2.8
2.3
0.75
1.45
31.9
18.6
2.6
2.1
2.4
0.75
1.39
32.2
19.7
1.9
0.79
1.78
30.3
13.6
3.8
2.7
0.77
1.66
30.8
15.1
3.6
2.5
0.77
1.60
31.1
16.0
3.3
2.2
4.5
0.81
2.02
29.6
11.2
3.1
4.3
0.80
1.89
29.9
12.4
2.8
4.2
0.79
1.83
30.1
13.0
2.5
0.85
2.30
29.3
9.4
5.8
3.5
5.6
0.83
2.16
29.4
10.2
3.1
0.82
2.09
29.5
10.7
5.4
2.8
0.87
2.57
29.4
8.1
7.3
3.8
7.0
0.87
2.44
29.5
8.6
3.4
6.8
0.86
2.40
29.5
8.9
3.1
Page 10
12
10
15
Heat Controller GeoMax 2
Performance capacities shown in thousands of Btuh.
HEATING - EAT 70°F
HC
KW
HE
LAT
17.3
1.46
12.3
90.0
-
19.1
1.51
14.0
92.1
-
19.8
1.51
14.6
92.9
-
20.1
1.51
15.0
93.3
-
21.8
1.56
16.5
95.2
-
22.6
1.57
17.3
96.2
-
23.1
1.58
17.7
96.7
24.6
1.64
19.0
98.5
25.6
1.64
20.0
99.6
26.2
1.65
20.5
100.3
27.5
1.66
21.9
101.9
28.7
1.66
23.0
103.2
29.4
1.67
23.7
104.0
30.5
1.68
24.8
105.3
32.0
1.68
26.2
107.0
32.7
1.69
27.0
107.9
33.7
1.70
27.9
109.0
35.3
1.71
29.5
110.9
36.2
1.71
30.4
111.9
36.9
1.72
31.0
112.7
38.8
1.73
32.9
114.9
39.9
1.74
33.9
116.1
Operation Not Recommended
Heat Controller, Inc.
Submittal Data
COP
HWG
1.9
3.48
2.4
2.1
3.71
2.4
2.1
3.84
2.4
2.2
3.91
2.4
2.2
4.08
2.5
4.22
2.3
2.5
2.4
4.29
2.4
2.4
4.40
2.6
2.5
4.57
2.6
2.6
4.64
2.5
4.87
2.7
2.6
2.7
5.06
2.7
5.16
2.8
2.6
5.34
2.9
2.8
3.0
5.56
2.8
5.68
3.1
2.8
5.82
3.1
3.0
3.2
6.06
3.0
3.3
6.20
2.9
3.3
6.30
3.2
6.57
3.4
3.2
3.6
6.73
3.1
Rev: 01/07/07JH