JVC InteriArt AV-21VT16/P Service Manual page 24

Jvc flat color television service manual
Table of Contents

Advertisement

4.8.5 VIDEO CIRCUIT
Measuring
Item
instrument
WHITE
Signal
BALANCE
generator
(Low light)
Remote
control unit
REMOTE CONTROL UNIT
B CUTOFF (
)
B CUTOFF (
)
WHITE
Signal
BALANCE
generator
(High light)
Remote
control unit
REMOTE CONTROL UNIT
R DRIVE (
)
R DRIVE (
)
SUB BRIGHT
Remote
control unit
SUB
Remote
CONTRAST
control unit
1-24 (No.YA453)
Test point
Adjustment part
[2. V/C]
2. CUTOFF (B)
2. CUTOFF (G)
SCREEN VR
[In HVT]
1
2
3
G CUTOFF (
4
5
6
7
8
9
G CUTOFF (
[2. V/C]
3. WDR (R)
3. WDR (G)
3. WDR (B)
1
2
3
G DRIVE (
)
4
5
6
B DRIVE (
)
7
8
9
B DRIVE (
)
G DRIVE (
)
[2. V/C]
4. BRIGHT
[2. V/C]
5. CONT
COMPOSITE WHITE BALANCE
(1) Receive a PAL black and white signal (COLOR off).
(2) Set the PICTURE MODE to BRIGHT.
(3) Select 2. V/C from the SERVICE MODE.
(4) Select <2. CUTOFF> (B) and (G).
(5) Set each value to initial setting value with the [4] / [7]
keys and [5] / [8] keys.
(6) Turn the SCREEN VR fully counterclockwise, then
slowly turn it clockwise to where a red, blue or green
COLOR is faintly visible.
(7) Use the [4] / [7] and [5] / [8] keys to adjust so that
the other 2 COLORs appear white.
)
(8) Turn the SCREEN VR to where the single horizontal
line glows faintly.
(9) Press the [OK] key to memorize the set values.
COMPONENT WHITE BALANCE
(1) Receive a PAL component black and white signal
)
(COLOR off).
(2) Select VIDEO-2 SET from the MENU and set
VIDEO-2 SET to COMPONENT.
(3) Adjust COMPONENT WHITE BALANCE in the
same way as "COMPOSITE WHITE BALANCE".
(1) Receive a PAL black and white signal (COLOR off).
(2) Set the PICTURE MODE to BRIGHT.
(3) Select 2. V/C from the SERVICE MODE.
(4) Select <3. WDR> (R), (G) and (B).
(5) Set each value to initial setting value with the [4] to
[9] keys.
(6) Use the [4] to [9] keys to produce a white screen.
(7) Press the [OK] key to memorize the set values.
(1) Receive a NTSC broadcast.
(2) Set the PICTURE MODE to BRIGHT.
(3) Select 2. V/C from the SERVICE MODE.
(4) Select <4. BRIGHT>.
(5) Set the initial setting value of <4. BRIGHT>.
(6) If the brightness is not best with the initial setting value,
make fine adjustment until you get the best brightness.
(7) Press the [OK] key to memorize the set values.
(1) Receive a NTSC broadcast.
(2) Set the PICTURE MODE to BRIGHT.
(3) Select 2. V/C from the SERVICE MODE.
(4) Select <5. CONT>.
(5) Set the initial setting value of <5. CONT>.
(6) If the contrast is not best with the initial setting value,
make fine adjustment until you get the best contrast.
(7) Press the [OK] key to memorize the set values.
Description

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents