SEBU9064
Table 5
Flash Code
13
22
33
04
Table 6
Flash Code
13
Table 7
Flash Code
31
22
33
Flash Codes with Key ON (Engine not in Operation)
Description
Oil pressure switch malfunction.
Disconnection of Oil pressure
switch.
Disconnection of Oil pressure
harness.
Pressure sensor malfunction.
Disconnection of Pressure sensor
connector.
Disconnection of Pressure sensor
harness.
Actuator position sensor
malfunction.
Disconnection of Actuator position
sensor connector.
Disconnection of Actuator position
sensor harness.
Actuator drive malfunction.
Disconnection of Speed sensor
connector.
Disconnection of Speed sensor
harness.
Flash Codes During Engine Cranking
Description
Speed sensor malfunction.
Disconnection of Speed sensor
connector.
Disconnection of Speed sensor
harness.
Flash Codes with Engine in Operation
Description
Oil pressure decline.
Weak signal from oil pressure
switch.
Short-circuiting.
Pressure sensor malfunction.
Disconnection of Pressure sensor
connector.
Disconnection of Pressure sensor
harness.
Actuator position sensor
malfunction.
Disconnection of Actuator position
sensor connector.
Disconnection of Actuator position
sensor harness.
Engine status
Engine will start, but the engine will
shut down after 180 seconds
Engine will start, but the engine go
to limp home mode.
Engine will start, but the engine go
to limp home mode.
Engine will not start.
Engine status
Engine will not start.
Engine status
Engine will go to limp home mode
but the engine may shut down.
The engine will go into limp home
mode.
The engine will go into limp home
mode.
Engine Diagnostics
Diagnostic Flash Code Retrieval
Operator Action
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Operator Action
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Operator Action
Check engine oil.
(1)
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
Check harness connection. If the
fault remains contact your Perkins
dealer or your Perkins distributor.
(continued)
27