STA-RITE Max-E-Therm® Operation & Installation Manual page 37

120/240 vac natural gas/lp gas pool & spa heater
Table of Contents

Advertisement

3 6
TEMPERATURE SETTING
The heater comes factory set at 78° F. for the pool mode and 100° F. for the spa mode. Using the up and down arrows,
you can set the thermostats to a minimum temperature of 65° F., or a maximum of 104° F. If you desire to heat only one
body of water, the thermostat is capable of an off mode. As an example, if you only wish to heat the spa and not the pool,
simply depress and hold the pool down arrow, and the thermostat will lower its setting to 65° F. then go to an off mode.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the upper jacket halves (see
2. Pull hair pin clips.
3. Press the clips and remove the control panel board dome. Locate the yellow
button on the corner of the control board.
4. Push the Max. Temp. Set Point button on the back of the control board
(see
Figure
36).
The following sequence should happen:
A. The unit will come on and the POOL ON light will come on.
B. Press the ▲ TEMP or ▼ TEMP pad (on TOP of the panel) to set
maximum pool temperature.
C. Wait up to 30 seconds; the POOL ON light will go off and the
SPA ON light will come on. To override the time delay, push the
Max. Temp. Set Point button again.
D. Press the ▲ TEMP or ▼ TEMP button on the control panel
and set maximum spa temperature to 104°F (40°C) or less.
E. Wait up to 30 seconds; the SPA ON light will go off and
the unit will shut down. To override the time delay, push
the Max. Temp. Set Point button again.
5. Reinstall and bolt up the upper jacket halves.
P/N S794
Figure
35).
Section 3. Operation
Figure 35.
Clips
2
1
Figure 36.
Rev. B 6-23-08

Advertisement

Table of Contents
loading

Table of Contents