Toshiba RAS-13SKV2-E Service Manual page 106

Split type
Table of Contents

Advertisement

No.
Part name
TE sensor (outdoor heat exchanging temperature sensor)
11
• Attachment
Install the sensor onto the straight pipe part of the condenser
output pipe.
Detail C for 10k
TS sensor (Suction pipe temperature sensor)
12
• Attachment
Install the senser onto the straight pipe part of the suction
pipe. Be careful for the lead direction of the sensor.
TD sensor (Discharge pipe temperature sensor)
13
• Attachment
With its leads pointed upward, install the sensor onto the
vertical straight pipe part of the discharge pipe.
TO sensor (Outside air temperature sensor)
14
• Attachment
Insert the outdoor air temperature sensor into the holder, and
install the holder onto the heat exchanger.
Detail A
TS sensor For 10, 16k
During the installation work (and on its completion), take care not to damage the coverings of
the sensor leads on the edges of the metal plates or other parts. It is dangerous for these
coverings to be damaged since damage may cause electric shocks and/or a fire.
After replacing the parts, check whether the positions where the sensors were installed are the
proper positions as instructed. The product will not be controlled properly and trouble will result
if the sensors have not been installed in their proper positions.
Procedure
Detail C for 13, 16k
Detail B
TD sensor For 10, 16k
CAUTION
CAUTION
– 106 –
FILE NO. SVM-10001
Remarks
Detail B
Detail A
• Shown in the above figure is the
model 16k.
• The sensor mounting positions
in the model 10, 13k are all
the same witth the sole excep-
tion of the TE sensor. Refer to
the figure shown on the left.
Detail A
TS Sensor For 13k
Detail B
TD Sensor For 13k
Arrow D
TO sensor
Arrow D
Detail C
TO sensor
holder

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents