Advertisement

Adjustment
14

Work clamp

.11
14

Basic position of the work clamp

.11.01
14 - 20
Requirement
When the clamp piece 1 is flush with the marking 2 there must be a clearance of 120 mm
between the clamp pieces 1 and 3.
2
1
4
Fig. 14 - 19
Loosen screw 4.
Move clamp piece 1 so that it is flush with the marking 2.
Tighten screw 4.
Loosen grub screws 5 and move clamp piece 3 in accordance with the requirement.
Tighten the grub screws 5.
120 mm
3
5