SERVICING INSTRUCTIONS

Removal of Covers
Remove the self tapping screws and slide the Heating Unit from outer
housing, access to all components is then available.
Burner
Model 38 MJ/h Heater
Circular Stainless Steel Burner: 64mm diameter
86mm in length
Burner Ports: 6 rows of 50 x O 1.43
Burner tube: Length 105mm
Diameter 25mm
Inlet diameter 13mm
Ignition
Press button ignition
Flame Safeguard
"CH 20psi. Chant CSA K-80" Electro Magnet and Thermocouple
Overheat System
Two Thermo Electric Switches marked:
"HF KSD020 1 250V-10A"
Switching point 72 degrees Centigrade
Solonoid Value
"CEME 55IOND3,3 SGI AIF 230V 50Hz P 6 Bar DN 3,3"
Adjustments
Pilot Nil
Aeration. Fixed.
Ignition. (Spark Gap) 6mm
ELECTRICAL
The heater is supplied with a 220-240V AC electrical power cord with
a 3 pin plug. This plug must only be connected to an earthed power
supply.
IMPORTANT
This product is fitted with a sealed electrical connection plug that is
compatible with the heater, the mains supply for Australia and meets
the requirements of international standards. This heater must be
connected to a supply voltage that is equal to that stated on the rating
label. If the mains connection plug or power cord becomes damaged
it must be replaced with a complete assembly that is identical to the
original, and this must be replaced by an authorised service centre. If
in doubt always consult a qualified electrician.
Rating Label
Fan heater
Voltage
Input Wattage
10
EH6883
220-240V AC - 50Hz
130W