Relay Board - Carrier CAPRI-280 Operation And Service Manual

Bus air conditioning equipment
Table of Contents

Advertisement

1.9 Relay Board -- Electronically Commutated DC Motors with 2-speed Input Signal
+
1
K1
2
3
K2
EF2 EF1
4
EF3 EF4
D2
D6
---
a. Relays
K1
Energizes evaporator fans 1 & 2.
K2
Energizes evaporator fans 3 & 4.
K3
Energizes evaporator fan 5.
K4
Energizes evaporator fan 6.
K5
Provides the evaporator fan high output
signal.
K 6
Provides the condenser fan high output
signal. (Not used).
K 7
Energizes condenser fans 1 & 2.
K 8
Energizes condenser fans 3 & 4.
K 9
Not used
K10
Not used
K13
Energizes the A/C clutch.
K14
Energizes unloader 1.
K15
Energizes unloader 2.
K16
Energizes the high low pressure failure.
K17
Energizes the heat solenoid valve.
K18
Energizes the alarm output.
K19
Energizes the booster pump.
K20
Energizes the motor fail light.
b. Thermal Circuit Breakers 24V
CB 1 Evaporator fan #1.
CB 2 Evaporator fan #2.
CB 3 Evaporator fan #3.
CB 4 Evaporator fan #4.
CB 5 Evaporator fan #5.
CB 6 Evaporator fan #6.
CB 7 Condenser fan #1.
CB 8 Condenser fan #2.
CB 9 Condenser fan #3.
CB10 Condenser fan #4.
CB11 Spare.
CB12 Spare.
CB13 A/c clutch, unloaders 1&2
motor fail, heat valve, pressure fail
& spare output.
5
K3
K7
6
K4
D81
K8
EF HIGH
SIGNAL
D14
D17
D26
EF6 EF5
Figure 1-5 Relay Board
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
15 Amp.
7
K9
K6
8
CF2 CF1
9
K10
10
D37
D38
D41
CF2 CF2
K24 K22 K21 K23
c. Connectors
EF1-EF6
Evaporator Fans.
CF1-CF4
Condenser Fans.
JP1
External evaporator & condenser fan
thermal overload connections.
JP2
Logic board connector.
JP3
Booster pump.
JP4
A/C Clutch, Pressure fault output,
Compressor High Pressure Switch.
JP5
High pressure fail, motor fail output,
heat valve.
JP6
Unloaders 1 & 2.
EF-HIGH SIGNAL
CF-HIGH SIGNAL
d. LEDS
D 2
Evaporator fans 1 & 2 are energized.
D 6
Evaporator fans 3 & 4 are energized.
D14
Evaporator fan 5 is energized.
D17
Evaporator fan 6 is energized.
D26
Condenser fans 1 & 2 energized.
D30
Condenser fans 3 & 4 energized.
D38
Condenser fans 5 & 6 energized. (Not used).
D51
A/C clutch output active.
D54
Unloader 1 output active.
D57
Unloader 2 output active.
D60
High low pressure failure.
D63
Heat valve output active.
D66
Alarm output active.
D69
D72
Motor fail light.
D81
Evaporator fans on high.
D85
Condenser fans on high. (Not used).
1-7
JP6
13
K14
K15
11
K16
K17
12
JP5
K18
K20
D85
JP4
CF
K13
K19
HIGH
SIGNAL
JP3
CF6 CF5
JP1
Output to the evaporator
fans to operate on high
speed.
Output to condenser fans to
operate on high speed.
(Not used)
D57
D54
D63
D60
D72
D66
D51
D69
JP2