MECHANICAL ADJUSTMENTS
3 7 63 1515 0
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
erase head
capstan
2. Demagnetize the record/playback head with a head
demagnetizer. (Do not bring the head magnetizer close to the
erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, appiy suitable locking compound to
the parts adjusted.
5. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
TORQUE MEASUREMENT
Mode
FWD
FWD
Back Tension
FF/REW
TAPE TENSION MEASUREMENT
Mode
TE
L 13942296513
FWD
www
.
http://www.xiaoyu163.com
SECTION 5
pinch roller
rubber belts
idlers
Torque Meter
Meter Reading
2.9 – 7.4 mN⋅m
CQ-102C
(30 – 75 g⋅cm)
(0.42 – 1.04 oz⋅inch)
0.14 – 0.59 mN⋅m
CQ-102C
(1.5 – 6.0 g⋅cm)
(0.021 – 0.083 oz⋅inch)
more than 5.4 mN⋅m
CQ-201B
(more than 55 g⋅cm)
(more than 0.76 oz⋅inch)
Tension Meter
Meter Reading
more than 90 g
CQ-403A
(more than 3.17 oz)
x
ao
y
i
http://www.xiaoyu163.com
ELECTRICAL ADJUSTMENTS
8
DECK SECTION
1. Demagnetize the record/playback head with a head
demagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjust.
TEST TAPE
Tape
P-4-A063
RECORD/PLAYBACK HEAD AZIMUTH ADJUSTMENT
Note: Remove the mechanical deck before the adjust. (Refer to Section 3.
DISASSEMBLY (See page 7))
Procedure:
1. Mode: Playback
test tape
P-4-A063
(6.3 kHz, − 10 dB)
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw
so that outputs match within 1dB of peak.
Q Q
3
6 7
1 3
L-CH
peak
Screw
position
3. Mode: Playback
test tape
P-4-A063
(6.3 kHz, − 10 dB)
u163
.
4. After the adjustments, apply suitable locking compound to the
pats adjusted.
HCD-SPZ50/SPZ70
SECTION 6
2 9
9 4
2 8
0 dB=0.775 V
Signal
6.3 kHz, –10 dB
Azimuth Adjustment
HP A-IN
PHONES jack
(J982)
set
1 5
0 5
8
2 9
9 4
within
1dB
Output
level
R-CH
peak
L-CH
R-CH
peak
peak
HP A-IN board
oscilloscope
PHONES jack
(J982)
set
waveform of oscilloscope
m
in phase 45 °
90 ° 135 ° 180 °
co
good
wrong
9 9
Used for
level meter
+
2 8
9 9
within
1dB
Screw
position
V
H