Read These Warnings First

Please read all installation requirements, installation procedures and precautions before
installing any Tudor water heater.
Never attempt to install any Tudor water heater without reading all of the applicable
instructions.
Tudor water heaters are open outlet (vented) water heaters and must not be installed in
the same way as mains pressure type water heaters.
The outlet from any Tudor water heater must be connected directly to an outlet spout on
the sink and must not be obstructed by a tap or valve or in any other way.
The water flow is controlled by a cold water tap connected before the water heater. Cold
water pushes hot water out of the tank when the cold water tap is turned ON. Any such
cold water tap should be labelled HOT.
This water heater must not be connected to more than one outlet.
All plumbing connections must be made in accordance with AS3500.
The heater is intended only for indoor use and should never be installed outdoors or be
exposed to the elements of nature.
Over-sink and under-sink models are NOT interchangeable.
Children should be supervised to ensure they do not play with the heater.
The heater is unsuited for use by children or infirm people without supervision.
If the power supply cord is damaged it must be replaced by a Service Provider or a
qualified electrician.
Do not remove the cover of the heater under any circumstances without first isolating the
heater from the power supply.
Outlet temperature should never be set to less than 60°C without due regard to regulations
governing the storage temperature of hot water.
This unit must not be cleaned by a water jet.
Before installing, ensure that the following are available:
a) sufficient space to position the heater so there is 270 mm clear access under the heater
(over-sink models) or 270mm above (under-sink).
b) standard 10 amp 240 volt power outlet within 1500 mm of the heater
c) cold water supply with a minimum working pressure of 50 kPa and a maximum working
pressure of 350 kPa.
d) Isolating valve (not supplied)
If the pressure may exceed 350 kPa, a 350kPa pressure limiting valve (not supplied) must
be installed in the cold water supply line.
A double check valve (not supplied) is required to comply with the backflow requirements
of AS/NZS3500.1
Under-sink models must be installed beneath approved vented mixer taps requiring a
single mounting point on a sink, basin or tub.
Water pressure under 100 kPa may be sufficient for over-sink heaters but may not operate
under-sink mixer taps satisfactorily.
Tudor - Installation & Operating Instructions - 85807 - June 2012 v1.00