12-2-12 Compressor wire missing error/rotation error
n I
o d
r o
d
s i
l p
y a
Outdoor display
1.Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Restart a er power
Is the restart error occurred again?
YES
Is the conne on of compressor
wire is normal? (PBA and
i
i
l? (
A
Compressor)
YES
Is the restart error occurred again?
YES
Is the compressor body and
interphase resistance insulated?
NO
Exchange the compressor
Samsung Electronics
Compressor wire missing error/rotation
4 E
7 6
error
Compressor wire missing error/rotation
error
d
NO
Terminate the service
NO
Connec he comp wire normally
NO
Terminate the service
YES
Exchange the Outdoor PBA
12-2-12