Outdoor Pcb - Samsung AR18HSFNBWKNEU Service Manual

Split-type air conditioner
Table of Contents

Advertisement

Outdoor PCB

2
EARTH - CN003
#1 : EARTH
4
CN051/052 - REACTOR
#1 : REACTOR1
#1 : REACTOR2
12
CN152 - SMPS IN
#1 : 12V
#2 : GND
#3 : 5V
CN551 - DOWNLOAD-INV
17
CN551 - DOWNLOAD-INV
#1~#10 : DOWNLOAD
Samsung Electronics
1
TB-N - CN001
#1 : N
14
CN901 - FAN MOTOR
#1 : DC 310~340V
#2 : N.C
#3 : AGND
#4 : DC 15V
#5 : FAN RPM
#6 : FAN FEEDBACK
10
U/V/W - COMP
U : U
V : V
W : W
13
CN153 - SMPS IN 15V
3
TB-L - CN002
#1 : L
6
CN251 - TEMP SENSOR
#1, #2 : OUT SENSOR
#3, #4 : DISCHARGE SENSOR
11
CN503 - EEV
#1~#4 : EEV SIGNAL
#5 : 12V
5
CN030 - 4-WAY
#1,#3 : AC220~240V
16
CN301 - COMMUNICATION
#1 : F1
#2 : F2
15
CN201 - DOWNLOAD-MAIN
#1~#10 : DOWNLOAD
8-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents