MQHB3636/4236/4736 Gas Conversion –Part A
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instruction s and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked
as specified in the manufacturer's instructions supplied with kit.
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
1.
Remove ember plates right and left of burner, ember plates are held in place by 2 screws each.
2.
Loosen screws from burner retainer tabs and slide burner to the left to remove from orifice.
3.
Remove main orifice using a 1/2" wrench and replace with new conversion orifice.
4.
Install new pilot orifice and Hi/Lo valve regulator by following instructions supplied with conversion kit.
5.
Adjust the primary air setting to the correct setting as specified in the manual or label plate. To adjust air setting, loosen screw on
the side of air mixing tube and rotate to the correct opening using a drill bit or tape measure. Retighten screw.
6.
Reinstall ember plates and burner by reversing steps 1 & 2.
1.
Remove false bottom and loosen the two [2] burner hold downs.
2.
Slide the burner tube towards the left to remove from orifice.
3.
Remove main orifice using a 1/2" wrench and replace with new conversion orifice.
4.
Install new pilot orifice and Hi/Lo valve regulator by following instructions supplied with conversion kit.
5.
Adjust the primary air setting to the correct setting as specified in the manual or label plate. To adjust air setting, loosen screw on
the side of air mixing tube and rotate to the correct opening using a drill bit or tape measure. Retighten screw.
6.
Reinstall ember plates and burner by reversing steps 1 & 2.
Caution:
Gas Conversion – MQRB4236