Fault Messages - Potterton Eurocondense Plus Installation Manual

Condensing sectional boiler
Table of Contents

Advertisement

FAULT MESSAGES

Table 12 Fault messages (display 13 flashing)
Display
flashing
Description
(Code-No.)
10
Outdoor temperature sensor short circuit or discontinuity Check connection and outdoor temperature sensor
20
Boiler flow sensor short circuit or open circuit
40
Boiler return sensor short circuit or open circuit
50
Hot-water sensor 1 short circuit or open circuit
52
Hot-water sensor 2 short circuit or open circuit
61
Fault, room control module RRG
62
Wrong room control module connected
81
Short circuit on LPB bus or no bus feed
82
Address conflict on LPB bus (EUROCONTROL)
91
EEPROM data loss
92
Hardware error
100
Two time master
110
Limit stat tripped
111
Max. temperature tripped
119
Water pressure switch tripped
132
Safety switch off
133
No flame detected (no flame message after
expiration of safety time)
134
Flame failure during operation
135
Incorrect air supply
140
Impermissible LPB segment number or equipment number Check setting on EUROCONTROL
148
Incompatibility between LPB interface/basic unit
151
Internal error in BMU
152
Error in BMU parameter settings
153
EUROCONDENSE EC PLUS disabled
154
Temperature fault
160
Fan speed error
161
Max. speed exceeded
180
Chimney sweep function active
181
Controller stop mode active
183
EUROCONDENSE EC PLUS in programming mode
Display of 3-digit error messages: The 1 in the number 100 is displayed alternately with the 10's position.
1) Switch off and disable; can be enabled only with Reset
2) Switch off, start prevention; starts backup after fault disappears
3) Check parameters according to Table 7 and program basic settings or
check value "b 0" (internal BMU-SW diagnostic code, Table 6) and correct parameter error according to error
specification!
4) Error display only, no switch off
50
Explanations
Possible causes and function sequence
2)
Check connection
2)
Check connection
Check connection; emergency operation
2)
Check connection
(not present)
Check room control module RRG
Connect compatible room control module
Check bus
Check addresses of connected control modules
Internal BMU error, process sensor, change BMU
Internal BMU error, process sensor, change BMU
Check EUROCONTROL timer master
Allow unit to cool down and reset. If fault occurs
several times, notify heating engineer
(possible short circuit in gas valve)
Not heat requirement, pump defective, radiator valves closed
Check water pressure and add water if required
e.g. contact F7 or F5 open
Reset, if fault occurs a number of time, notify heating engineer,
insufficient gas (see Page 20), check polarity of line power
connection, ignition electrodes and ionization current
Automatic restart attempt by PARAMOUNT
Fan speed above or below speed threshold
Check setting on EUROCONTROL
Check parameters (Tables 7 and 8), heating engineer
Repeat parameter settings
1)
Press reset button
Parameter incorrectly set (Tables 7 and 8), check parameters
or boiler temperature too high
1)
Fan speed not reached
Max. fan speed exceeded
4)
4)
1)
2)
1)
temperature stat open circuit
3)
2)
1) 2)
2)
1) 2)
1) 3)