Water Level Control; How Water Level Control Works; Purpose; To Replace Water Level Control - Cornelius 500 Series Installation And Service Manual

Hide thumbs Also See for 500 Series:
Table of Contents

Advertisement

Continuous Flow Icemaker Installation and Service Manual

WATER LEVEL CONTROL

H
W
L
OW
ATER
EVEL
When water is introduced through the inlet fitting the float rises. the float pushes against a lever which in turn forces
the poppet assembly against the inlet fitting valve seat which seals the water off. See Figure 5. Before the water inlet
is sealed the safety switch is operated. In the event of a water failure the float would drop down and operate the safety
switch to shut off the machine.
If the water level control does not shut off and seal at level, as indicated, be sure inlet pressure does not exceed
recommended factory operating range.
Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted when the unit
was installed or relocated. If however, the control becomes inoperative, repair or replace it. See Start-Up Adjustment,
page 7.
P
URPOSE
1. To automatically maintain proper water level in the evaporator when unit is running and making ice.
2. A safety switch is operated in the event of an interruption in water supply. The switch shuts off the electrical
power to the icemaker and its refrigeration system. Switch will reset as soon as cause of water failure has been
corrected and proper water level in icemaker has again been reached.
3. The transparent bowl not only provides a visible check of water level, but also is a good guide to the internal
conditions which exist within the icemaker assembly itself. (See Cleaning Procedure.)
T
R
W
O
EPLACE
ATER
1. Shut off the water supply, Shut off the main power switch or unplug the ice dispenser from electrical outlet.
2. Remove the flexible tubing from bottom of water level control and drain water from water level control and evap-
orator.
3. Remove flexible tubing at bottom of water level bowl connected to the overflow.
4. Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.
5. Remove the wing nut holding the water control to its mounting bracket. Control can be removed by lifting
straight up.
T
R
W
O
EPLACE
ATER
1. Shut off the main power switch or unplug the ice dispenser from electrical outlet.
2. Unplug molex connector connecting switch to electrical box.
3. Remove the two (2) screws anchoring the water level safety switch to the bottom of the water level control
mounting bracket.