TO START EN GIN EWITH WEAK BATTE RY
_,WARNING:
Lead-acid batteries gener-
ate explosive gases.
Keep sparks, flame
and smoking materials away from batteries.
Always wear eye protection when around
batteries.
Ifyour battery is too weakto start the engine, it
should be recharged. (See "BATTERY" in the
MAINTENANCE
section of this manual).
If "jumper cables" are used for emergency
starting, follow this procedure:
IMPORTANT:
Your tractor is equipped with
a 12 volt system. The othervehicle must also
be a 12 volt system. Do not use your tractor
battery to start other vehicles.
TO ATTACH JUMPER CABLES -
1. Connect one end of the RED cable to the
POSITIVE (+) terminal of each battery(A-
B), taking care notto short against tractor
chassis.
2. Connect one end of the BLACK cable
to the NEGATIVE (-) terminal (C) of fully
charged battery.
3. Connect the other end of the BLACK
cable (D) to good chassis ground, away
from fuel tank and battery.
TO REMOVE CABLES, REVERSE ORDER -
1. BLACK cable first from chassis and then
from the fully charged battery.
2. RED cable last from both batteries.
Weak or
Dead
Battery
Fully
Charged
Battery
REPLACING
BATTERY
AI_WARNING: Do notshortbatteryterminals
by allowing a wrench or any other object to
contact both terminals
at the same time.
Before connecting
battery, remove metal
bracelets, wristwatch bands, rings, etc.
Positive terminal must be connected first to
prevent sparking from accidental grounding.
1. Lift seat pan to raised position.
Seat
2. Disconnect BLACK battery cabte firstthen
RED battery cable and carefully remove
battery from tractor.
3. Install new battery with terminals in same
position as old battery.
4. First connect RED battery cable to posi-
tive (+) terminal with hex bolt and keps
nut as shown. Tighten securely. Slide
terminal cover over terminal
5. Connect
BLACK
grounding
cable to
negative (-) terminal with remaining hex
bolt and keps nut. Tighten securely.
Positive
(Red)
Cable
Terminal
Cover
Keps
Nut
aex
Bolt
Negative (Black)
Cable
26