State Of Charge - Maintenance-Free Batteries; Charging System Tests - Motorola; Ignition On - Engine Not Running; Field Draw Test - Ignition Off - Ford LSG 875 Service Manual

Lsg 875
Table of Contents

Advertisement

4-06
CHARGING
4-06
TESTING (Continued)
STATE OF CHARGE -
MAINTENANCE-
FREE BATTERIES
Read the battery open circuit terminal voltage
with
a digital voltmeter capable
of
reading
l/100 of
a volt. If the open circuit voltage of the battery is
below 12.40
volts and the battery has passed the
capacity test, charge the battery.
CHARGING
SYSTEM
TESTS
MOTOROLA
The following tests are made with the alternator
on the engine with output and regulator connec-
tions maintained
to the alternator except as noted
in Tests 3 and 5. The field lead and voltage reg-
ulator are disconnected
for these tests.
CAUTION:
-
DO NOT disconnect alternator output lead
while alternator is operating.
-
DO NOT disconnect voltage regulator while
alternator is operating.
-
DO NOT ground field terminal.
-
Check
battery
condition.
Use a fully
charged battery when testing alternator.
-
Disconnect ground cable of battery when
removing and installing the alternator.
All readings
indicated
are for correct operation.
Test 1 -
Ignition On -
Engine Not Running
Correct voltage at regulator terminal is approx-
imately
1.5 to 2.5 volts.
This
test evaluates
excitation
circuit.
If voltage at regulator
terminal
is:
5.0 to 7.0 volts = open rotor (field circuit)
.75
to 1.1 volts = grounded
rotor circuit
8.5
to 10.0 volts = open in regulator' s
load
circuit
0 volts = open ignition switch or excitation
resistor
If test results are uncertain,
go to Test 2.
Test 2 -
Ignition On -
Engine Not Running
The voltage regulator may be bypassed with a
short jumper between the regulator and field ter-
minals. If jumper
provides
approximate
correct
voltage, fault is in the regulator. No change from
high voltage
indicates
that the defect is in the
brush or rotor circuit.
DC VOLTS
Test 3 -
Field Draw Test -
Ignition Off
This test evaluates
complete field circuit, inde-
pendent of voltage
regulator.
Circuit
is through
brushes, slip rings, field coil to ground.
Current
should be 2 to 2.5 amps. If less than this, check
brushes and slip rings. It is desirable to use a field
rheostat in series with meter for protection of the
meter. If field is shorted, excessive
current would
flow through meter and possible damage would
result.
NOTE: On integral regulator units, remove reg-
ulator to disconnect field connection. Reg-
ulator and ground
terminals
to remain
connected.
DISCONNECTED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents