2. Top Vent - Vertical Termination - (continued)
2 ELBOWS
Note: Flue restrictor is permit-
ted ONLY on 30 ft. minimum
vertical runs with no elbows.
Figure 4.10
V
2
H
1
Heatilator • HEIR36, HEIR42, HEIR50 Installation Manual • 2285-980 Rev. G • 12/14
WARNING! Risk of Fire!
• HEIR36(NG/LP), HEIR42(NG/LP) and HEIR50(NG/LP) models
require a minimum of 24 inches of vertical venting before attaching
any elbow to the appliance.
DO NOT attach elbow directly to the appliance.
HEIR36 (NG/LP), HEIR42 (NG/LP), HEIR50 (NG/LP)
2 ft
3 ft
4 ft
5 ft
6 ft
*No specifi c restrictions on this value EXCEPT
V
V
1
V
H
1
1
610 mm
1 ft
305 mm
914 mm
3 ft
914 mm
1.2 m
4 ft
1.5 m
9 ft
1.8 m
12 ft
V
+ V
+ H
= 50 ft (15.2 m) Max.
1
2
1
+ V
+ H
cannot exceed 60 ft (18.3 m).