Honeywell LYNX Touch Series Installation And Setup Manual page 30

Hide thumbs Also See for LYNX Touch Series:
Table of Contents

Advertisement

LYNX Touch Installation and Setup Guide
Programming the Control
SCREEN
Device Type
Response Type
Not Used
Alarm Report
Yes
Chime
No
Supervision
Supervised
Device Type
Select "Device Type". The system displays the following options (dependant upon the Device
Type selection):
New
Window
Glass Break
Heat Sensor
Use the down
arrow to scroll to the next page of options:
Temperature
Environmental
Fire
Garage Door
Response Type
1. Select "Response Type". The system displays the specific options, which are dependant
upon the Device Type that was selected for the zone. Use the down
next page of options. Use the
Not Used
Entry Exit 2
Interior Follower
24 Hour Silent
24 Hour Auxiliary
Interior With Delay
Carbon Monoxide
Arm Stay
Disarm
Silent Burglary
Resident Response
General Response
Day/Night
2. Select the desired Response Type and select "Save". The system will return to the Zone
screen.
Note:
For threshold monitoring to be configurable on the LYNX Touch Z-wave thermostat screen, the
respective zones will first need to be assigned with a response type in zone programming. The
recommended response type is Trouble.
Alarm Report
Note: This field is for Alarms. If Response Type "Trouble" is set up and Alarm Report is set to
"No" the system will still report if Report Alarms was enabled in the Reporter
programming.
Select "Report" to toggle between "No" or "Yes". Select "Save".
Chime
Note: Chime only applies to entry/exit, perimeter and interior zone types.
Select "Chime" to toggle between "No" or "Yes". Select "Save".
Supervision
The system displays the applicable Supervision options based upon the Device Type that was
selected. Select "Supervision" to scroll between the following options:
Hardwire Zone
Normal Open
Normal Closed
End of Line
RF Zone
Supervised
Unsupervised
Temperature (Defaulted for Zones 80-85)
High Temp (Default selection for Zones 80, 82 and 84)
Low Temp (Default selection for Zones 81, 83 and 85)
After making a Supervision selection, select "Save".
ACTION
Door
Motion Sensor
Smoke Detector
Carbon Mono. Det.
Flood
Medical
Police
Other
arrow to return to the previous page.
Entry Exit 1
Perimeter
Trouble
24 Hour Audible
Fire No Verification
Monitor
Garage
Arm Away
No Response
Resident Monitor
General Monitor
Fire With Verification
Garage Monitor
- 30 -