1.
DANGER
!
Risk of fire or explosion. DO NOT start or fuel the fire using
garbage, gasoline, drain oil or other flammable liquids or
chemicals.
WARNING
!
SAFE DOOR OPERATION:
OUTER DOOR
Always keep outer door closed and latched during normal
operation. When door is open always secure door with
door stop rod.
LOADING DOOR: ALWAYS OPEN SLOWLY
1. Move LEVER above loading door to the left, timer
comes on, wait momentarily and SLOWLY open
loading door. Timer will shut down the furnace after
5 minutes. To reset timer, move lever to the right and
then back to the left. Lever in the right position puts
the furnace into the normal running mode, timer is
then locked out.
2. After loading CLOSE and LATCH door firmly and move
LEVER to the right. DO NOT operate with loading door open.
ASH REMOVAL DOOR: ALWAYS OPEN SLOWLY
1. ALWAYS switch furnace off before opening door.
DO NOT operate with ash removal door open.
2. CLOSE and LATCH door firmly.
- For safety keep firebox loading door and ash door
tightly closed.
- Follow listed combustibles installation clearances.
- DO NOT store fuel or other combustible materials within
the marked installation clearances of the furnace.
- Inspect and clean flues and chimney regularly.
- Follow complete installation, operating and cleaning
instructions in the Operator's Manual.
CAUTION
!
- Hot surfaces do not touch.
- KEEP CHILDREN at safe distance.
- DO NOT damage furnace. Load wood carefully.
- DO NOT add fuel during a power outage.
- KEEP water level above the add mark.
- Place ash in metal containers and away from
combustible materials.
2.
EMPYRE ELITE XT HYDRONIC FURNACE
EMPYRE ELITE XT - FOURNAISE HYDRONIQUE Á BRÛLAGE PROPRE
Model No./Certifién de Modèle
100
200
Serial No./ N° de Série ___________________________
Certified Heating Appliance CSA Standard B366.1-M91 UL Standard 391-2006/726-06 Standard C22.2 No. 3
Appareil de Chauffage Norme B366.1-M91 de la CSA Norme 391 de ULC - 2006/726-06 Norme C22.2 No 3
Empyre Elite XT 100/200 #702112231 or #70626288
Empyre Elite XT 100/200 no 702112231 ou no 70626288
WN20717
EMPYRE ELITE XT INSTALLATION AND OPERATION MANUAL
3.
817970R00
817978R00
15
2
1
Front View
Front View
4.
5.
WARNING
!
ELECTROCUTION HAZARD
ALWAYS SECURE DOOR WITH LATCH.
TIGHTEN WITH WRENCH.
6.
2
3
Red
Orange
Black
6
5
Probe-
2 wire
black
cable
1
2
7 8
10 11
Probe
Power
Com NO
10
Yellow
4
8
7
Blue
Red
White
White neutral line
Black power line
SAFETY
7.
SPECIFICATIONS
Install and use only in accordance
with the manufacturer's installation/
operating
instructions
codes. If there are no applicable local
codes, an outdoor installation chimney
must be listed to the ULC-S610 and
ULC-S604 standard and an indoor
installation must follow ANSI/NFPA
211 and NFPA90B. Chimney must
be a listed UL 103 HT or ULC S629
residential all-fuel type or tile-lined
masonry. Flue connector pipe must
be made of a minimum 24 NSG black
steel. Special precautions are required
for passing the chimney through a
combustible wall or ceiling. Refer
to authorities having jurisdiction for
proper installation.
Minimum Clearance to Combustibles
Side Wall to Furnace
Back Wall to Furnace
Front of Furnace to
Combustibles
Combustibles to Flue
Ceiling to Furnace
Floor*
815541
* For indoor installation a noncombustible
liner must be placed under the furnace.
CAUTION
!
Wiring Diagram
818492 - R0
-
DO NOT connect the unit to a
1.
Limit Switch - 815822
2.
Blower Switch - 800836
chimney flue that serves another
3.
Indicater Light - 806481
appliance.
4.
Timer Unit - 817482
5.
Temp Controller A - 810268
-
DO NOT burn trash in this furnace.
6.
Probe Well - 806455
-
DO
NOT
7.
Snap Disc - 816271
8.
Blower - 814185
furnace.
9.
Furnace Power Cord
-
DO NOT dump ash close to any
10.
Probe - 812424
combustible materials.
-
The heat exchanger, flue pipe,
chimney must be in good condition
and cleaned regularly to remove
accumulated creosote and ash.
-
Clean at the end of the heating
season
to
during summer months.
-
Follow cleaning instructions in
1
Operator's Manual.
-
Refer to Operator's Manual for
complete instructions.
In the event of loss of electrical power:
1. Open all check and zone valves in
Purple
the system. Depending on system
design, this may allow convective
Red
4
3
circulation.
White
2. It is important to remember that
2
the heating system cannot dispose
Blue
1
of a great deal of heat without the
circulators running. Avoid over firing!
DO NOT LOAD LARGE AMOUNTS OF
SOLID FUEL INTO THE FURNACE!
Fire the furnace cautiously until you
are able to determine how quickly
the heat system is able to dissipate
}
110 volts
the heat being produced by the
AC 60Hz
furnace.
Ground
9
3. When the power has returned,
reset all check and zone valves and
resume normal operation of the
system.
In the event of a runaway fire:
1. Ensure the firebox door is tightly
closed.
2. Close all the combustion air inlets
on the furnace.
To cool an overheated furnace:
1. Turn all thermostats to their highest
temperature setting.
4
3
7
5
6
Rear View
Rear View
and
local
12" (305 mm)
12" (305 mm)
48" (1220 mm)
12" (305 mm)
24" (610 mm)
0" (0 mm)
pressurize
water
in
minimize
corrosion
817971R00
7