Stamina 55-1532A Owner's Manual page 7

Gravity inversion therapy table
Hide thumbs Also See for 55-1532A:
Table of Contents

Advertisement

ASSEMBLY INSTRUCTIONS
STEP 3
Slide the bottom of the two PIVOT ARMS(5) into the brackets located at each side of the MAIN FRAME(4).
Align the desired hole on the arm with the peg on the bra cket, and insert the peg into the hole to lock the
PIVOT ARMS(5) in position. Then secure the PIVOT ARMS(5) on the pegs with ROUND HEAD BOL TS
(M6x1x10mm)(38) and LARGE WASHERS(M6)(44).
PIVOT ARM ADJUSTMENT:
There are three adjustment holes on the PIVOT ARMS(5) allowing you to position the MAIN FRAME(4) at
three different heights. The lowest hole will allow the le ast amount of inversion a ngle. The top hole will allow
the greatest amount of inversion angle.
CAUTION:
1.
Use the lowe st holes in the PIVOT ARMS(5) until you be come familiar with the Gravity
Inversion Therapy Table.
Both PIVOT ARMS(5) must be a djusted to the sa me hole. Trying to a djust the PIVOT
2.
ARMS(5) to different positions could cause damage to the machine, and injury to the user.
STEP 4
Attach the MAIN FRAME(4) with the adjusted PIVOT ARMS(5) onto the REAR FRAME(2) by sliding the
slots in the ends of the two PIVOT ARMS(5) into the slots on the REAR FRAME(2).
SLOTS
7