1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
Source
Remote Controller (option)
Controller P.C.B. Ass'y
Fan (Number...diameter)
Fan Motor
Model...Nominal output
Source
No. of pole...r.p.m. (230 V, High)
Coil resistance
(Ambient temperature 20 °C)
Safety device
Operating temperature
Run capacitor
Electronic refrigerant control valve
Solenoid control model
Coil resistance (at 20 °C)
Solenoid control valve model
Heat exchanger
Coil
Rows...fin pitch
Face area
Auto louver motor
Auto louver motor...Raterd
Coil resistance (at 25 ˚C)
Dew proof heater
mm
W
rpm.
BRN – WHT
WHT – VLT
VLT – ORG
Open °C
Close °C
VAC, µF
ORG – GRY
RED – GRY
mm
m
2
V, Hz, W, rpm.
V, W
– 13 –
1. Specifications
1. Specifications
SPW-T363GH56
220 - 230 - 240 V / 1 phase / 50 Hz
RCS - SH80TG (Microprocessor)
CR - X253GH (Microprocessor)
Centrifugal (4...ø150)
KFG4Q - 101D5P...100 W
220 - 230 - 240 V / 1 phase / 50 Hz
4...1,194
:
43.3
,
ORG – YEL
:
16.6
,
VLT – PNK
:
24.5
130 ± 5 °C
Differential 15 deg. (min.)
440 V, 4.0 µF
EKV - MOZS559E0
:
46
,
YEL – GRY
:
46
,
BLK – GRY
HKV - 30D16
Aluminum plate fin / Copper tube
3...1.7
0.34
MC8 D
220 - 240 VAC, 50 Hz, 3 W, 3.3 rpm. 8P
14,900 Ω ± 8 %
240 V, 17 W
1
: 349.3
1
:
40.8
:
46
:
46
SM830034