Remote Controller - Battery Installation; Remote Controller - Synchronisation; Remote Controller - Manual Operation - Rinnai R2339 Operation Manual

Sapphire gas log flame fire wireless remote/thermostatic controller
Table of Contents

Advertisement

REMOTE / THERMOSTATIC CONTROLLED OPERATION

REMOTE CONTROLLER - BATTERY INSTALLATION

Carefully remove the battery compartment cover panel from the rear of your controller hand-set
and correctly insert the two AA batteries supplied ensuring '+' and '-' polarity is correct.
When installing your batteries your remote control will display the 'Initial Set-up Screen'. The
screen will display the following:
Current room temperature in °C
Default time setting of
Default day of the week setting 'MO' - Monday.
When batteries are changed all settings other than synchronisation are lost and the controller will
revert back to the 'Initial set -up screen'.
NOTE
Synchronisation must be carried out when a new controller has been purchased. The heater will
not respond or operate to any function until synchronisation has been carried out.

REMOTE CONTROLLER - SYNCHRONISATION.

Before proceeding with synchronisation ensure that the gas and electricity are connected.
Two controllers CAN NOT be used at the same time!
NOTE
Synchronisation of Controller & The Heater
Step 1).Turn the power off at the power point for a minimum of 30 seconds, synchronisation will not be
possible unless the minimum 30 seconds has been observed.
Step 2).Ensure the remote control is turned OFF, to turn OFF press and release the 'PWR' button once.
Step 3).Turn the power ON at the power point, the blue power operation indicator
button control panel will flash once. The controller can now be synchronised with the heater.
Step 4).On the controller in quick succession press the following sequence
of buttons: 'P' > 'T' > 'T' > 'UP'.
The LCD display will show 'L/C' (Learn Code) for 2 seconds then
return to the normal 'OFF' state display. The blue power operation
indicator
on the push button control panel will flash once to
b
indicate that synchronisation has been accepted.
To restore factory default settings
With the thermostat 'OFF', press the following sequence of buttons 'P' > 'T' > 'T' > 'DOWN'.

REMOTE CONTROLLER - MANUAL OPERATION

Turning 'ON' and 'OFF'
Press 'ON'/'OFF' button of the Push Button Control Panel
Press the 'OK' and 'PWR' button at the same time to turn 'ON'/ ignite the heater. This is a safety feature to reduce
the accidental activation of the heater.
The unit first lights the pilot and then after a short period switches to the 'HIGH' flame setting.
To turn 'OFF' press and release the 'PWR' button once.
Changing the temperature
The Sapphire has temperature increments of 1° which can be changed using the 'UP' and 'DOWN' buttons.
The temperature control range is 7 - 32°C
Change between Celsius - °C and Fahrenheit - °F
The thermostat temperature display can be set to °C or °F. The default is °C.
With the controller 'OFF', press the following sequence of buttons: 'P' > 'T' > 'T' 'A/M' to toggle between °C or °F.
Change between manual, automatic and flame modes
Press and release the 'A/M' button.
Rinnai Australia
once the Power Indicator LED
a
3
on the push
b
Synchronisation MUST
BE performed within 30
NOTE
seconds of the power
being turned ON, if more
than 30 seconds has
elapsed repeat steps 1
through 3.
, will illuminate blue.
b
Sapphire Controller Operation Manual
a
b

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents