Baxi Combi 80e Installation And Servicing Instructions page 41

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

E
Check and correct if necessary
1. Electrical and pressure tube connections
2. Blockage of pressure tubes
3. Restriction in flue
4. Venturi
F
NO
Gas at burner
G
1.
Check the burner setting pressure of
the gas valve
(see Section
2.
Voltage at modulating coil of gas valve is:
Max. burner press.approx 9V DC (13V DC LPG)
Min. burner press.approx 1V DC
Current at modulating coil of gas valve is:
(Use an instrument with average function for this
measure)
30 ÷ 230 mA DC (45 ÷ 310 mA DC LPG)
H
Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
NO
Ensure gas is on and purged
PCB - A1 connector has 230V AC
across terminals 2 & 4
NO
neon iflashing
NO
Replace PCB
of Commissioning)
230V at Main PCB - A1
YES
connector across terminals
3 & 5. Check wiring
14.0 Fault Finding
Replace air
pressure switch
YES
Replace gas valve
YES
Turn selector switch
to reset position
YES
Replace gas valve
NO
Replace PCB
NO
Replace PCB
YES
Replace igniter
R
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combi 105e

Table of Contents