CONTROL PANEL (located under the cover at the rear of the opener)
1. External Accessory Power: 30 Vdc 50 mA available for universal receiver (not active in Low standby mode).
2. Terminal Block: used for external accessories (see chart below).
No
Function
E-Serial port
0
Push button
1
2
Ground
Ground
2
IR Sensor
3
Door-in-door
4
Door-in-door
5
Flasher
6
Flasher
7
3. UP Button: used for initial programming, to drive the door UP, and for displaying Diagnostic Code - Digit 1.
4. PROG Button: used to program door limits, and other features.
5. DOWN Button: used for initial programming, to drive the door DOWN, and for displaying Diagnostic Code - Digit 2.
6. LEARN Button: used to program remote controls and learn the forces manually.
7. Indicator LED: used to indicate various programming modes.
7
Colour Polarity Comment
Green
+ve
Serial Communication Input
Red
+ve
Dry Contact input for push button wired wall controls
White
-ve
Common terminal for push button
White
-ve
Common terminal for IR Beams
Gray
+ve
Merlin IR Beam Input: (pulsing type only)
Green
+ve
For Door in Door dry contact sensor: (4&5 are normally linked)
Green
-ve
Common terminal for Door in Door sensor
Black
+ve
Flashing light output: (24 Vdc 150 mA) while door is in motion
White
-ve
Flashing light output: negative terminal
1
0
1
2
30 V DC
+
-
INDICATOR
LED
LEARN
(YELLOW)
6
2
2
3
4
5
6
7
UP
PROG
DOWN
5
5
3
4