11.5.2
OFF Timer Control
OFF timer can be set using remote control, where the unit with timer set will stop at set OFF time.
Notes:
1
By pressing ON/OFF operation button, the ON Timer or OFF Timer setting will not be cancelled.
2
To cancel the previous timer setting, press CANCEL button.
3
To activate the previous timer setting, press SET button.
4
If main power supply is switched off, the Timer setting will be cancelled.
11.6 Random Auto Restart Control
•
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes. There are 10 patterns to be selected randomly after power supply resumes.
•
This control is not applicable during OFF/ON Timer setting.
•
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
11.7 Indication Panel
LED
Color
Light ON
Light OFF
Note:
•
If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
•
If TIMER LED blinks, there is an abnormal operation occurs.
POWER
TIMER
Green
Orange
Operation ON
Timer Setting ON
Operation OFF
Timer Setting OFF