CONNECTION
Standard signal generator
0.1 V to 32 mV
( 127 dBm to 17 dBm)
CAUTION:
DO NOT transmit while
an SSG is connected to
the antenna connector.
FM
Attenuator
deviation meter
40 dB or 50 dB
RF power meter
0.1 10 W/50
Frequency
DC POWER CABLE CONNECTIONS
NOTE:
When you adjust the output power (high
power), the battery type detector must be con-
nected to GND (see illustration at above).
Ohterwise the transceiver does not transmit high
power, the output power will be low.
to the antenna connector
counter
to [MIC]
to an RS-232C port
OPC-478
DB9 female plug
(incl. level converter circuit)
to [SP]
JIG cable
+
Battery type detector
Battery type detector
5 - 3
Audio generator
Personal
computer
SINAD meter
Speaker (8
)
DC POWER
SUPPLY
GND