Document Revision 4C
90-12-06
System Alarm Output – Output Mode
0 = Manual (default)
1 = Auto
90-24-01
System Alarm Report Notification Time Setup – Month
Set the month (00~12)
(0 = Disabled)
90-24-02
System Alarm Report Notification Time Setup – Day
Set the day (00~31)
(0 = Disabled)
90-24-03
System Alarm Report Notification Time Setup – Hour
Set the hour (00~23)
(0 = Disabled)
90-24-04
System Alarm Report Notification Time Setup – Minute
Set the minute (00~59)
(0 = Disabled)
For Printing Reports
90-12-01
System Alarm Output – Output Port Type
Indicate the connection used for the System Alarms. The baud rate for the COM port should be
set in Program 10-21-02.
0 = No Setting (default)
1 = COM Port (CPUII)
2 = -- Not Used --
3 = -- Reserve --
4 = CTA/CTU
90-12-02
System Alarm Output – Destination Extension Number
If the output port type (PRG 90-12-01) is set to CTA, enter the extension number with the CTA
connection.
Extension Number (up to eight digits)
No default is assigned
90-12-03
System Alarm Output – Output All Alarm Reports
0 = Disable (Off) (default)
1 = Enable (On)
90-12-04
System Alarm Output – Printout New Alarm Reports
Print New?
0 = No
1 = Yes
2 - 38
Electra Elite IPK II
Alarm Reports