Specification Of 16I - Rinnai REU-16 Service Manual

Continuous flow water heater
Table of Contents

Advertisement

Specification of 16i

Type of Appliance
Operation
Flue System
Installation
Available Temps
Width
Dimensions
Height
Depth
Weight
Gas
Connections
Cold Water
Hot Water
Ignition System
Noise Level
Nox
Water Temp Control
Flame Failure
Boil Dry
Remaining Flame
Safety Devices
Over current
Over pressure
Combustion Fan
Fusible Link
Over temperature
Heater Mounted
Remote Controls
Kitchen
Bathroom
Remote Cable
G20 Nat Gas Press Low
G20 Nat Gas Press High
G25 Nat Gas Press Low
G25 Nat Gas Press High
G30 LPG (Butane) Press Low
G30 LPG (Butane) Press High
G31 LPG (Propane) Press Low
G31 LPG Propane) Press High
Gas Consumption Low (Gross)
G20 Nat Gas
G25 Nat Gas
G30 LPG (Butane)
G31 LPG (Propane)
Gas Consumption High (Gross)
G20 Nat Gas
G25 Nat Gas
G30 LPG (Butane)
G31 LPG (Propane)
Max Flow raised 25C
Min Operation Flow
Water Pressure Nom.
Power Supply
Electric Consumption
Temp Controlled Continuous Flow Gas Water Heater
With / Without remotes (Kitchen, Bathroom, etc.)
Room Sealed, Forced Draught Flue
Internally Mounted only
37C - 48C (1 deg Increments) 50, 55, 60
370 mm
675 mm
130 + 45 mm
15 kg
1/2 in bsp
1/2 in bsp
1/2 in bsp
Direct Electronic Ignition
49 dB(A)
55 ppm Max
Simulation feed forward and feedback
Flame Rod
Water Flow Sensor
97 C bimetal switch
Glass Fuse 3 Amp
Pressure Relief Valve 15 bar open, 12 bar close
Integrated circuit system
150 C Thermal Fuse
Lockout Thermistor 95 C
MC-45-SR-EU
BC-45-SR-EU or BSC-45-SR-EU
BC-45-SR-EU or BSC-45-SR-EU
Two core sheathed (double insulated) flex with min 0.55 mm
1.8 mbar
9.0 mbar
1.8 mbar
9.0 mbar
2.2 mbar
11.4 mbar
2.2 mbar
14.2 mbar
4.7 kW
4.0 kW
4.9 kW
4.9 kW
34.9 kW
29.6 kW
36.8 kW
36.5 kW
15.2 L/min
2.4* L/min
1.1 - 7.0 bar
230 V / 50 Hz
68 Watts
7
2
0.4 m3/hr
0.4 m3/hr
0.35 kg/hr
0.35 kg/hr
3.26 m3/hr
3.26 m3/hr
2.6 kg/hr
2.6 kg/hr