Technical Specifications; Power Supply Specifications; Networking Standards Supported - RuggedCom MediaConverter Installation Manual

Mediaconverter
Table of Contents

Advertisement

Technical Specifications

3 Technical Specifications

3.1 Power Supply Specifications

Power Supply Type
24 VDC
48 VDC
HI (88/300 VDC)
1
HI (120/240 VAC)
1
Notes: 1 – This is the same power supply for both AC and DC.
2 – (T) Denotes time-delay fuse

3.2 Networking Standards Supported

Parameter
IEEE 802.3
IEEE 802.3u
IEEE 802.3x
TIA/EIA 785
All RuggedMC
products feature Link Pass Through support. When loss of link is detected on
TM
either the fiber side or the copper side, link pulses are no longer transmitted on any of the
RuggedMC
ports. This feature allows for prompt loss of link detection and user correction. The
TM
faulty link partner can be identified by loss of link on the RuggedMC
RuggedCom
®
Minimum
Maximum
Input
Input
18 VDC
36 VDC
36 VDC
72 VDC
88 VDC
300 VDC
85 VAC
264 VAC
10FL
Module
Module
14
Internal
Maximum Power
Fuse
Rating
3.15A(T)
2
3.15A(T)
2
3.15A(T)
2
100FX
10BaseT
100BaseTX / 100BaseFX
Full Duplex Operation
10/100BaseSX Capable
front panel indicators.
TM
RuggedMC™ RMC Installation Guide rev105
Consumption
3 W
Notes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmc-100-mmRmc-10-mmRugged mediaconverter series

Table of Contents