Silent Alarm; Reporting Options - Paradox Esprit 728 Installation Manual

Hide thumbs Also See for Esprit 728:
Table of Contents

Advertisement

Memory display and auto zone shutdown are always active for silent zones (when enabled at
address 206, key [
TRBL
Silent alarms can be monitored by a PGM output. (Silent flag is cleared on report or disarm.)
On split reporting, silent zones/panic are reported to Telephone #1.
The Contact ID report for all zones is "burglary".
Dialing pulse rates
This selection reflects the ratio between pulse time and "quiet" time. Select Pulse Europe for a 1:2 ratio
(Key [10] = "off"), Pulse USA for 1:1.5. (Key [10] = "on")

Reporting options

Regular reporting
To activate central station reporting, the feature must be enabled and all required reporting codes, except
when using "Ademco contact ID (all codes reported)", must be assigned a value other than [2
To establish communication, the communicator takes the telephone line and waits for a dial tone. If a dial
tone is identified, the communicator will dial the first central station telephone number. If a connection is
made, system report will take place and the communicator will hang up upon completion. If for any rea-
son, communication is interrupted, the communicator will dial the 2nd central telephone line and report
only the events that were not reported during the interrupted attempt.
During a communication attempt, the communicator waits for a dial tone for up to 8 seconds. Even if a
dial tone is not found, the communicator will dial the central station.*** After 60 seconds, if communi-
cation has not been established, the dialer will hang up, wait 5 seconds and try the second number. This
sequence will be repeated 8 times, switching back and forth between the 1
reporting dialing procedure: 1,2,1,2,1,2,1,2, "communicator report failure".)
***This feature is useful for PBX systems, which do not provide a dial tone. You can program the dialing
sequence required to get a line on a PBX system, and this sequence will be added before the central
station number. If there is a time delay between dialing and getting a line, this can be programmed
into the dialing sequence using the [
After 8 unsuccessful attempts, the redial sequence ends and "communicator report failure" will appear in the
keypad's trouble display (key [7] "on"). When the next reportable event occurs, (even if it is not programmed
to report to the central), the communicator will again try to establish communication. If successful, all events
stored in the event buffer that have not yet been reported will be communicated to the central.
Split reporting
All "system" reports (i.e. trouble reports, arm/disarm reports, etc.) are sent to Telephone #2, until an alarm is
generated. Following alarm generation, all activity, including alarm and restoration reports, is sent to Telephone
#1 until the system is disarmed. When there is an alarm, any ongoing communication (upload/download or
reporting to Telephone #2) will immediately be stopped and the panel will dial Telephone #1.
"System" reports dialing procedure:
Alarm reports dialing procedure:
Double reporting
The panel will transmit all reports to both programmed telephone numbers. If, after 8 attempts using either
number, communication is not established, "communicator report failure" will be displayed by key [7].
Double reporting dialing procedure:
Note: To stop communication attempts until the next reportable event, press [
Bell squawk
Bell/siren will emit a 0.5 second "squawk" once upon arming, and twice upon disarming.
(Key [
] "on" = enabled)
MEM
].)
(Address 206, key [10])
(Address 206, key [11] and key [12])
] ("pause") key.
MEM
(Address 206, key [11] "on", key [12] "off")
(2,2,2,2,2,2,2,2, "communicator report failure")
(1,1,1,1,1,1,1,1, "communicator report failure")
(Address 206, key [11] "on", key [12] "on")
(1,1,1,1,1,1,1,1, "communicator report failure")
(2,2,2,2,2,2,2,2, "communicator report failure")
(Address 206, key [
18
ND
st
and 2
nd
number. (Regular
] + installer code + [
ENTER
])
MEM
IM728-738
][2
].
ND
].
STAY

Hide quick links: