Fire Circuit; Telephone Line Connection - Paradox Esprit 728 Installation Manual

Hide thumbs Also See for Esprit 728:
Table of Contents

Advertisement

Exception:
When the zone definition is "24 hour", the tamper definition follows the audible/silent
alarm arm definition of the "24 hour" zone.
Tamper recognition addresses:
Tamper report and restoration codes should be programmed at addresses 191 and 180.

FIRE CIRCUIT

The fire zone (enabled by defining zone 3 as "24 hour') should always be connected
W
with a 1K
EOL resistor (PN201100200-PRT on UL systems). If there is a line short
in the fire zone, a fire alarm will be generated. If the line is "open", a "fire loop" trouble
report will be sent to the central and trouble indicator [11] will illuminate on the keypad.
For UL/ULC installations, a 4 wire, latching, smoke detector (UL - Falcon Model 5454,
ULC - BRK Model 2412) must be used. To supervise power supply, an "end of line"
relay (Model MR3) is installed. This relay's contacts will cause a FIRE TROUBLE in
the event the power is interrupted.
To reset (unlatch) smoke detectors after an alarm, power to detectors must momen-
tarily be interrupted. To do so, connect the negative (-) side of smoke detector power
to PGM1. PGM1 should then be programmed "Timed N.C." (normally closed), pro-
grammed to "open" when any two keys on the keypad are pressed simultaneously.
Example:
To program
to conduct smoke detector reset when
1
PGM
[
] and [
] are pressed at the same time.
CLEAR
ENTER
Address 195 = [
] (in the first digit)
BYP
Address 196 = [5] [10]
Address 198 = [2
] [6]
ND
Address 254 = [10] [10] [4]

TELEPHONE LINE CONNECTION

Connect the incoming telephone company wires into
"
" and "
". Wires should then be run from "
TIP
RING
"
1" to the installation's phone system.
R
POWERING UP THE UNIT
When keypads are installed far from the control panel, a keypad should be temporarily connected close
to the panel to conduct "power-up" testing. Connect the transformer. After 5 seconds, begin testing the
unit. Enter random commands on the keypad. It should "beep" in response to these commands. Open a
zone to ensure that keypad and panel are responding to signals. If the keypad does not respond and
indicator lights do not illuminate, check for AC voltage at the "AC" terminals. If 16VAC is flowing, then
keypad wiring should be verified. Also check for a short between "black" and "red" keypad wires.
1" and
T
10
IM728-738

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esprit 738

Table of Contents