Removing The Front Panels - Viessmann VITODENS 222-F Installation Instructions Manual

Floor mounted, gas-fired condensing storage combi boiler
Table of Contents

Advertisement

Boiler Connections
Connections
(continued)
16
Vitodens 222-F, B2TA 19 and 35 Installation

Removing the front panels

1. Tilt the lower front panel.
2. Remove the retaining screw and set aside.
3. Lift up and out to remove the lower front panel.
4. Loosen the screws at the bottom of the boiler as
shown (do not remove completely).
5. Remove the front upper panel.
6. Move the boiler to the location where it is to be
installed.
7. Using the adjustable legs level the unit.
CAUTION
The boiler must be level both vertically and horizontally
to ensure proper draining of the condensate.