Download Print this page

Salus ERT 50 Instruction Manual page 2

Programmable room thermostat
Hide thumbs Also See for ERT 50:

Advertisement

PROGRAM-MENU
Program Menu
To access the program-menu press
the – or + button, open the hatch and
press select and cancel at the same
time for three seconds.
Profile
Enter the Profile-Menu to adjust the detailed settings of the Family, Single, Office, Name 1 and Name 2 Profiles.
You can adjust the profiles to your needs, by varying the 6 daytimes and allocate them new temerature zones. This
can be done for a single day or week and weekend. You can rename profiles and copy settings inside a profile and
from one profile to an other. In the following table, you can find the preinstalled settings:
Heat/Cool
Enter the Heat/Cool-Menu to activate the
Heat or Cool function of the device.
Basic Settings
Enter the Basic Settings-Menu to
adjust Date/Time, Language and
Maintenance settings.
Daytimes
Time
Eearly Morning
06:00 - 08:00
Morning
08:00 - 12:00
Noon
12:00 - 14:00
Afternoon
14:00 - 18:00
Evening
18:00 - 23:00
Night
23:00 - 06:00
Eearly Morning
06:00 - 08:00
Morning
08:00 - 12:00
Noon
12:00 - 14:00
Afternoon
14:00 - 18:00
Evening
18:00 - 23:00
Night
23:00 - 06:00
Control
Enter the Control-Menu to make changes on the
Span, SetBack, Frost*, Output and VP settings.
* Thermostat serves as protection against frost
and keeps temperature constant at 5°C.
Temp. Zones
Enter the Temp. Zones-Menu to adjust the temperatures of the Com-
fort, Standard and Reduced zones.
The three temperature zones can be allocated to the six day times.
If you modify a temperature zone, the temperature-settings within
the profiles will change as well. The zones are preinstalled with these
temeratures:
Comfort 24°C
Standard 20°C
Reduced 16°C
Family
Single
Office
Name 1
Comfort
Comfort
Comfort
Comfort
Standard
Standard
Standard
Standard
Comfort
Comfort
Comfort
Comfort
Standard
Standard
Standard
Standard
Comfort
Comfort
Comfort
Comfort
Reduced
Reduced
Reduced
Reduced
Comfort
Comfort
Comfort
Comfort
Standard
Standard
Standard
Standard
Comfort
Comfort
Comfort
Comfort
Standard
Standard
Standard
Standard
Comfort
Comfort
Comfort
Comfort
Reduced
Reduced
Reduced
Reduced
DATA SPECIFICATION
2 x Batteries Type AA (intern)
Supply:
230V AC / 50Hz (extern)
Electronic switch output
Switching current max.:
10 (2) A
Number of actuators, max.:
5 units - 3W
Hysteresis:
0.5K
Protective class:
IP 30
Dimensions W/H/D in mm:
75/130/30
Temperature range:
5°C - 30°C
Storage temperature:
-25°C - 65°C
Purpose and correct use:
This standalone mounted electronic device
serves as a temperature control system only in
dry and closed living and office spaces. Clean
device only with a dry and soft cloth. Do not
use solvents or aggressive cleaning agents!
The manufacturer accepts no responsibility
for damage caused by non-observance of
these instructions.
Changing the batteries
2 x +AA Batteries
Name 2
Comfort
Standard
Comfort
Standard
Comfort
Reduced
Comfort
Standard
Comfort
Standard
Comfort
Do not dispose of batteries with
Reduced
general household refuse. Please take
battery to municipal collection point
or dispose with trade waste.
WIRING PLAN
Terminal
Supply for temperature reduction
N
Neutral wire
L
230 VAC supply
Switch output (actuator, terminal strip)

Advertisement

loading