Haier HWD-C1200TXVE-U Service Manual page 20

Front load washing machine
Hide thumbs Also See for HWD-C1200TXVE-U:
Table of Contents

Advertisement

SERVICE MANUL
HWD-C1200TXVE-U
Error message:Temperature sensor is not properly connected or damaged (display at the end of a
program).
Troubleshooting:
Cut off power and measure the resisitance
of temperature sensor by multimeter,is
it between 5-14k ?
Y
Check if NTC is connected properly
Y
Check the black wire and blue wire of NTC,
are they connected well ?
Y
Disconnect the white wire and black wire
from PCB
,and measure if the resistance
between white wire and black wire
N
Repalce power driver PCB
Error message:The heater may be broken
Troubleshooting:
Cut off power,check the resisitance of
Turn on power, and set wash mode ,then start.
Check the export voltage of power driver
of
y
Y
Haier
N
N
N
Y
Heater elelment
must be
N
broken,please
replace it
220-240V
Washing
Machine
NTC exist open circuit
Connect NTC well
Connect all wires well
Repalce wire
Power
driver PCB
must be
Y
broken ,plea
se replace it.

Hide quick links: