E. Non-Combustible Sealant Material
• After completing the installation of non-combustible
material in the required non-combustible zone and the
non-combustible fi nishing material over that, remove the
template.
• A bead of non-combustible sealant (or Super Calstick)
must be used to close off any gaps at the top and sides
between the fireplace and non-combustible facing
(Figure 7.6) to prevent cold air leaks and the risk of fi re.
Large gaps can be bridged with fi berglass rope gasket.
• W hen installation of the decorative material is complete,
replace/install the fascia and fi replace doors.
NON-COMBUSTIBLE ZONE
45-1/4 in.
(1150 mm)
47-1/2 in.
)
(1207 mm
7100
Figure 7.6
WARNING! Risk of Fire!
• Maintain clearances.
• Use only non-combustible material below standoffs,
material such as cement board is acceptable.
• Framing or fi nishing material used on the front of
the fi replace closer than the minimums listed, must
be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
WARNING! Risk of Fire!
Hearth & Home Technologies is not responsible for
discoloration, cracking or other material failures of
fi nishing materials due to heat exposure or smoke.
• Choose fi nishing materials carefully.
Seal inside perimeter of
fireplace finished opening
with non-combustible
grout to prevent risk of fire
and cold air infiltration.
Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev G • 5/27/14