The Grand Voyager Zero Clearance Box allows the product to be installed into a combustible wall, with minimum clearances and without brick or block work using the framing dimensions and clearances illustrated below. Zero Clearance Box Dimensions ...
Page 3
Zero Clearance Box Assembly Details Step 1 Step 2 Lay down the bottom panel with folded Screw rear spacer, inner left, inner right edges facing upwards, and the non- and inner back panels together, with the folded edge turned frontwards. ...
Page 4
Step 8 Step 7 Stainless bend is supplied to match Screw the 250mm collar in place the height of the triple skins. The triple skin flue must be installed with a Zero Clearance Box, as per Australian standards.
Page 5
Framing Dimensions for Zero Clearance Box ...
Page 6
Hearth Requirements for Zero Clearance Box 30
575
560
40
...
Minimum Clearances & Hearth Requirements for Zero Clearance Box SECTION VIEW
...
Page 8
Minimum Clearances & Hearth Requirements for Zero Clearance Box ELEVATION – MANTEL CLEARANCES PLEASE NOTE: These specifications relate to Zero Clearance installations only. For installations into an existing fireplace, refer to the Voyageur Grand Installation Manual. JETMASTER HEAT & GLO 444 Swan Street, Richmond.