WIRING
WARNING: Turn power off at circuit
breaker or fuse. Place tape over circuit
breaker switch and verify power is off at
the fixture.
1. Connect the house wires to the terminal block
according to diagram (see Figure 4). Make
sure all screws on terminal block are tightened
securely.
2. Remove the strain relief cover and place the house
wires across the strain relief (see Figure 5).
3. Replace the strain relief cover and tighten
securely. Note: Be careful not to overtighten
and damage the wiring.
Terminal Block
From Fixture
Brown
Blue
Green/Yellow
Terminal Block
Strain Relief
Cover
Screw
House Wiring
From AC Source
Red or Brown
Blue or Black
Green/Yellow
Figure 4
Figure 5

FINAL ASSEMBLY

1. Double check all wiring connections.
2. Verify the rubber gasket is properly seated
around the edge of the canopy extension (see
Figure 6).
3. Align the center hole on the fixture canopy
with the center hole on the canopy extension
and attach using the mounting bolt removed
in step 1 of Installation (see Figure 6).
IMPORTANT:
• If wall mounted, make sure the fixture is
mounted with the sensor below the bulb
holders.
• If eave mounted, mount the fixture with
sensor facing away from the house wall (see
Eave Installation Information for important
sensor orientation information).
4. Push the rubber plug firmly into place (see
Figure 7).
5. Caulk around top half of canopy extension
with silicone weather sealant (see Figure 7).
6. Install bulb. Do not exceed wattage rating on
fixture label.