doMESTIC WaTER HEaTING oPERaTIoN

In this mode, domestic water heating will be activated as required by the water temperature set point.
• The set point can be set manually.
1. Press Power (DHW mode) button to turn on DHW
tank.
The priority between heating/cooling/water-law and
DHW modes are depending upon the user's input of
Field Setting Value of Wired Remote Controller.
The default priority is on the DHW mode.
• T his mode can not be used when the DHW tank is
not installed.
• T he Power (Space mode) button and the Power
(DHW mode) button can be selected at the same
time.
• I n order to provide domestic hot water throughout the day, it is advised to keep the
domestic water heating operation on continuously.
• W hen the
panel. The operation between solar panel and heat pump can be determined by using
Wired Remote Controller's Field Setting Mode.
2. Press Mode (DHW mode) button until required operating mode is displayed.
The heat pump will run on selected domestic water heating mode.
• E conomic domestic water heating
• Standard domestic water heating
• Powerful domestic water heating
3. Press Up or Down button to set the desired temperature.
The temperature can be set between 30ºC and 70ºC.
The temperature is adjusted by 0.5ºC.
RC120MHXGA_IB_E_34412A(1).indd 19
icon is displayed, hot water is delivered to the DHW tank by the solar
(
(
operate immediately)
may operate)
Operating basic function _19
2012-02-08 오후 2:35:40