Operation; Grid Rack Seasoning Instructions; Lighting Instructions - Garland G18-BRL Installation And Operation Manual

Garland g-brl & gf-brl series broilers
Hide thumbs Also See for G18-BRL:
Table of Contents

Advertisement

OPERATION

Grid Rack Seasoning Instructions

To insure long life and service, it is imperative that the
cooking surface be carefully broken in or seasoned in the
following manner:
1 . Remove all factory applied protective material by
washing with hot water and a mild detergent or soap
solution . Rinse and dry thoroughly .
2 . Apply a thin coat of olive oil or other high grade salt free
cooking oil to the cooking surface . Wipe away excess .
3 . Turn all valves to a low setting and allow grid racks to
heat slowly for thirty (30) minutes . Allow oil to remain on
cooking surface three (3) to four (4) minutes, then wipe off .
4 . Reset valves to desired operating temperature and apply
a second coat of oil and leave for two (2) or three (3)
minutes after grid rack reaches temperature . Then wipe
off surplus .
Your broiler is now ready to use .
NOTE: Unless products contain sufficient fat, grid racks must
be seasoned before each use . Re-season after thorough
cleaning of the cooking surface .

Lighting Instructions

Models G(18,24,39,36,48)-BRL
1 . One pilot serves two burners and is located between
those burners .
2 . Push red spark buttons several times to ignite pilot
burners .
3 . Ensure pilots are lit by viewing through pilot view hole on
front of unit .
Part # 4525958 (10/28/08)
Models GF(18,24,30 .36)-BRL
1 . Push in the valve knob and turn counter-clockwise to the
ignition position .
2 . While holding the knob fully in, depress the ignitor
button and visually confirm that the pilot lights are on .
If the pilot does not light, repeatedly press the ignitor
button until ignition is achieved .
3 . After the pilot is lit, continue to hold the valve knob in for
at least 20 seconds, then release it . If the pilot goes out,
wait five, (5), minutes, then repeat the procedure .
4 . When the pilot is established, push in the valve knob
again and turn it counter-clockwise to the full flame
position, igniting the main burner .
5 . For low flame or simmer, push in the valve knob and turn
it to the low flame position .
6 . To turn the burner off, push in and turn the valve knob to
the circular "OFF" symbol .
Shut down
1 . Turn all gas valves off .
2 . If the unit is to be shut down for an extended period of
time, turn the in-line service valve to the "OFF" position,
(this valve is not factory supplied) .
Page 11

Advertisement

Table of Contents
loading

Table of Contents