Operating Instructions; Self Diagnostic Electronic Control Module - Amana GUI* User's Information Manual

Gas fired warm air furnace
Table of Contents

Advertisement

Operating Instructions

1. Close the manual gas valve external to the furnace.
2. Turn off the electrical power supply to the furnace.
3. Set room thermostat to lowest possible setting.
4. Remove the louvered door on the front of the furnace by
lifting up and pulling it forward.
5. This furnace Is equipped with an ignition device which
automatically lights the burner. Do not try to light burner
by hand.
6. Honeywell, White Rodgers Model 36E36, and
Robertshaw Gas Valves:
Turn the gas control knob clockwise
position (Figure 2, 3 or 5). The knob should turn easily
by hand. Do not use excessive force.
White Rodgers Model 36E22:
Push the selector switch to "OFF". (Figure 4)
7. Wait five minutes to clear out any gas. Then smell for
gas, including near the floor. This is important , because
some types of gas are heavier than air.
8. Honeywell, White Rodgers Model 36E36, and
Robertshaw Gas Valves:
If you smell gas following the five minute waiting period
in Step 7, follow the instructions on the cover of this
manual. If you do not smell gas, then turn the gas con-
trol knob counterclockwise
(Figure 2, 3 or 5). The knob should turn easily by hand.
Do not use excessive force.
White Rodgers Model 36E22:
Push the selector switch to "ON". (Figure 4)
9. Replace the door on the front of the furnace.
10. Open the manual gas valve external to the furnace.
11. Turn on the electrical power supply to the furnace.
12. Set thermostat to desired setting.
NOTE: There is a delay between thermostat energizing and
burner firing.
Honeywell
Model VR-8205
to the OFF
to the ON position
Figure 2
White Rodgers
Model 36E36 Type 230
Redundant
Solenoid
INLET
ON/Off
Switch
Inlet Pressure Tap
Main Regulator
(Side of Valve)
White Rodgers
Model 36E22
Gas Control
Valve Lever
(In ON Position)
INLET
Inlet Pressure Tap

Self Diagnostic Electronic Control Module

Certain furnace models are equipped with a self-diagnostic
electronic control module. If a furnace component is not op-
erating properly, the control module will repeatedly flash a
red light on and off in a factory-programmed sequence, de-
pending on the problem encountered.
If a furnace equipped with a self diagnostic module is not
operating properly, look through the observation window in
the blower access door and make note of the number of
flashes in the sequence. Contact a qualified servicer for fur-
ther information. Do not attempt to troubleshoot the prob-
lem yourself.
6
Figure 3
WR
Solenoid
M
1
P
3
O
F
F
OUTLET
C
2
ON
Outlet Pressure Tap
(Side of Valve)
Adjust
Figure 4
Outlet Pressure Tap
(Side of Valve)
OUTLET
Pressure Regulator
Adjustment (Under
Cap Screw)
Figure 5
Robertshaw
Model 7222
Main