FITTED EQUIPMENT- The Alde Heating System
Bleeding:
If a bleeder screw is fitted to the outgoing
pipe, open this bleeder screw and leave it
open until it starts to discharge water. Start
the LPG boiler. The circulation pump should
be switched off. To help the system to bleed
quicker turn the pump up to 5.
Open the remaining bleeder screws in the
system. Leave the bleeder screws open until
they start discharging fluid, and then close
them. Start the circulation pump and let it run
for a while. Check that the pipes and radiators
around the vehicle are heating up.
If they fail to heat up try the following:
Single axle caravan: Stop the circulation
pump. Lower the front of the caravan as far
as possible. Leave it in this position for a few
minutes to allow the air to travel upwards in
the system. Open the bleeder screws at the
highest point. Leave it open until it discharges
glycol fluid. Raise the front of the caravan
as high as possible and repeat the procedure
in this position.
Then position the caravan
horizontally and start up the circulation pump.
Check that the pipes and radiators around the
vehicle are heating up.
Twin axle caravan:
The easiest way to bleed
the heating system is to place the vehicle on
a sloping surface or to raise one end of the
vehicle using a jack.
Bleed the system as
described above.

Troubleshooting:

The Boiler Does Not Start
• Check that the fuse spur is switched on.
• No LPG? Incorrect type for the conditions.
• Is the main tap fully open?
• If the boiler has not been operated for
some time, or if the gas cylinder has been
changed, it may take longer than normal to
light the boiler.
• Check that the boiler is connected to the
electricity supply (> 11V).
• Check that the fuse (T) for the boiler is
intact.
• Check whether the electric connections to
the boiler are securely in position.
• If none of the above helps, contact a service
workshop
Instructions for use of the main control panel

Starting the Boiler.

• When the screen is blank both the control
panel and the boiler are turned off.
• To start the boiler, press On/Off button and
the start-up display is displayed. The boiler
starts with the last selected setting.

From standby mode to setting menu

The background lights up when you press the
screen or the MENU button. Start the setting
menu by pressing the MENU button. The
background lights up and those functions which
can be set are displayed.
The settings are
automatically saved for 10 seconds. The control
panel reverts to standby automatically after
30 seconds if no buttons are pressed (or if the
MENU) button in the setting menu is pressed.)