6-2 TSD AND OLP
Normal operation of
compressor is
impossible or poor.
Separate TSD-Starter
from compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
tester.
(Figure 19)
Shows continuity
Separate OLP from
compressor and check
resistance value
between two terminals
of OLP with a tester.
(Figure 20)
Figure 19
- 21 -
Observation value is
115V/60Hz : 6.8
Ω
±30%
The resistance value
is 0
Ω
(short) or
∞ (open).
Check another
electric component.
Open
Replace OLP.
Figure 20
Replace
TSD-Starter.