Installation - Potterton Gold Installation And Servicing Instructions

Unvented mains pressure water heaters 100, 120, 150, 170, 210, 250 and 300 litre capacity direct and indirect models
Table of Contents

Advertisement

DIRECT MODELS
FUSED (13A) DOUBLE
POLE ISOLATING
SWITCH
1.5mm
3 CORE
2
HOFR SHEATHED
CABLE
Note: On models fitted with two elements each element must be
wired individually in accordance with the diagram above.
Fig. 7: Electrical connections (schematic)
INSTALLATION - DIRECT UNITS
PLUMBING CONNECTIONS
POTTERTON GOLD direct cylinders require the fol-
lowing
pipework connections.
Cold water supply to and from inlet controls.
Outlet to hot water draw off points.
Discharge pipework from valve outlets to
tundish
ELECTRICAL SUPPLY
100 litre direct Potterton Gold units are fitted with
one 3kW immersion heater, all other direct mod-
els are fitted with two 3kW immersion heaters as
standard. It is recommended that these should be
wired via a suitable controller to BSEN 60730. The
POTTERTON GOLD MUST be earthed.
All wiring to the unit must be installed in accordance
with the latest IEE Wiring Regulations and the circuit
must be protected by a suitable fuse and double
pole isolating switch with a contact separation of
at least 3mm in both poles. The live and neutral
connections are made directly onto the combined
thermostat and thermal cut-out located under the
terminal cover(s) mounted on the side of the unit.
The earth connection should be made to the earth
connection located to the side of the immersion
heater boss(es). The supply cable must be routed
through the cable gland located on the unit casing
beneath the terminal housing.
operate the immersion heaters until the
DO NOT
cylinder has been filled with water.
10
EARTH
CONNECTION
B
A
THERMOSTAT
(FIG. 6)
INDIRECT MODELS
INDIRECT THERMAL
CUT-OUT
1
2
GREEN/
YELLOW
DIRECT
THERMOSTAT
B
A
BROWN
13 AMP MAINS
SUPPLY. 1.5mm
BLUE
MIN. CABLE SIZE
SAFETY
DISCONNECT FROM THE MAINS SUPPLY
BEFORE REMOVING ANY COVERS.
Never attempt to replace the immersion heater(s)
other than with the recommended Potterton Gold
immersion heater(s).
DO NOT BYPASS THE THERMAL CUT-OUT(S)
IN ANY CIRCUMSTANCES. Ensure the two
male spade terminations on the underside of the
combined thermostat and thermal cut-out are
pushed firmly onto the corresponding termina-
tions on the element plate assembly.
In case of difficulty contact service support;
contact details available at the back of this
booklet.
INDIRECT
THERMOSTAT
2 3
1
TERMINAL
1 2
3
BLOCK
GREEN/
YELLOW
TO INDIRECT SYSTEM
2
CONTROLS JUNCTION
BOX - SEE FIGS. 8/9