Built-In Fireplace Installation - Desa CGEFP33PRA Owner's Operation And Installation Manual

Unvented gas fireplace with total control system (tcs)
Table of Contents

Advertisement

INSTALLATION
Continued
11. Carefully insert fireplace into cabinet mantel (see Figure 33).
Be careful not to scratch or damage hearth base, cabinet man-
tel, or any laminate trim on hearth base. Remove protective
material from top of hearth base and from front of fireplace (if
any). Note: You can secure fireplace to hearth or floor. Open
lower louver. Locate screw holes in bottom of base. Tighten
wood screws through these holes and into hearth or floor.
12. Check all gas connections for leaks. See Checking Gas Con-
nections, pages 17 and 18.
Figure 31 - Installing Cabinet Mantel
Figure 32 - Location of Nailing Flanges (EFP33PRA Shown)
Figure 33 - Inserting Fireplace Into Cabinet Mantel (EFP33PRA
Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110149-01A

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace
into a framed-in enclosure. This makes the front of fireplace flush
with wall. If installing a mantel above the fireplace, you must follow
the clearances shown in Figure 37, page 20. Follow the instructions
below to install the fireplace in this manner.
Cabinet
Mantel
1. Frame in rough opening. Use dimensions shown in Figure 34
2. Install and properly ground GA3555, three-prong 120 volt elec-
3. If not already completed, install gas piping to fireplace location.
4. Carefully set fireplace in front of rough opening with back of
5. Attach flexible gas line to gas supply. See Connecting Fire-
6. Plug electrical cord(s) into electrical outlet installed in step 2.
7. Carefully insert fireplace into rough opening.
Nailing Flanges
Figure 34 - Rough Opening for
Installing in Wall
Conventional Fireplace Installation (Cont.)
Built-In Fireplace Installation
Actual
Height
32
Front Width 34
Depth
16
for the rough opening. If installing in a corner, use dimensions
shown in Figure 35 for the rough opening. The height is 33"
which is the same as the wall opening above.
trical outlet, in fireplace. Follow instructions included in kit (see
Accessories, pages 42 and 43).
This installation includes an approved flexible gas line (if al-
lowed by local codes) after the equipment shutoff valve. The
flexible gas line must be the last item installed on the gas pip-
ing. See Installing Gas Piping to Fireplace Location, page 15.
fireplace inside wall opening.
place to Gas Supply, page 16.
3
17
/
"
4
33"
1
35
/
"
2
INSTALLATION
Framing
3
/
"
33"
8
5
1
/
"
35
/
"
16
2
3
11
/
"
17
/
"
16
4
3
39
/
"
8
1
35
/
"
2
5
55
/
"
8
Figure 35 - Rough Opening
for Installing in Corner
19
19
7
27
/
"
8

Hide quick links:

Advertisement