Kenwood TK-3102G Service Manual page 23

Uhf fm transceiver
Table of Contents

Advertisement

Common Section
Item
Condition
1. Setting
1) BATT terminal voltage: 7.5V
2) SSG standard modulation
[Wide]
MOD: 1kHz,DEV: 3kHz
[Narrow]
MOD: 1kHz,DEV: 1.5kHz
2. VCO lock
1) TEST CH: High
voltage
RX
2) TEST CH: Low
3. VCO lock
1) TEST CH: High
voltage
PTT: ON
TX
2) TEST CH: Low
PTT: ON
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: Center
adjust
PTT: ON
2. DQT/QT
1) TEST CH: Center
Balance
PTT: ON
3. RF Power
1) TEST CH: Low
BATT terminal voltage: 7.5V
PTT: ON
4. Max
1) TEST CH: Center
Deviation
AG: 1kHz/120mV
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
TX-RX
ANT
TX-RX
meter
CV
DVM
TX-RX
Measurement
Test-
Unit
Terminal
Unit
equipment
Frequency
TX-RX
ANT
counter
Power
TX-RX
meter
Deviation
meter
Oscillo-
scope
Power
meter
Ammeter
Power
ANT
TX-RX
meter
SP/MIC
Deviation
connec-
meter
tor
Oscillo-
scope
AG
AF VTVM
TK-3102G
Adjustment
Parts
Method
TC2
3.7V
±0.1V
Check
1.0V or more
TC1
3.7V
±0.1V
Check
1.0V or more
Adjustment
Parts
Method
Program-
Center frequency
Note: After replacing the
ming
±50Hz
TCXO (X1) align frequency.
software:
KPG-55D
(Windows
version:
ver.4.00
or later)
VR500 Adjust the demodu-
lation wave into a
square wave.
Program-
4.1W
±0.1W
ming
1.8A or less
software:
KPG-55D
(Windows
version:
ver.4.00
or later)
VR501 4.2kHz
±0.1kHz
(According to the
larger +,-)
Check
±1.8kHz~2.2kHz
Specifi cations / Remarks
Specifi cations / Remarks
23

Hide quick links:

Advertisement

Table of Contents
loading