T7300F SERIES 2000 COMMERCIAL MICROELECTRONIC CONVENTIONAL
OR HEAT PUMP THERMOSTAT
Installer Setup
Number
(Press
Unoccupied
Temp key
to change)
Select
Not used.
13
Degree
14
temperature
display.
Displaying
15
temperature.
Clock format.
16
Intelligent
17
Fan™
operation.
Auxiliary
18
Contact
Operation.
Extended fan
19
operation in
a
heating
.
Extended fan
20
operation in
cooling.
Fan key adjust-
21
ment (models
with Fan key).
Remote
22
sensing.
Temperature
23
averaging
b
network
.
Not used.
24
Keypad lockout
25
level (keypad
lockout is
enabled and
disabled by dip
switch 1 on
back of
thermostat).
a
Number 2 must be set to 1 to extend fan operation.
b
Number 22 must be set to 1 and remote sensor(s) must be installed.
62-0125—3
Table 2. Thermostat Installer Setup Options (Continued).
Factory Setting
Display
Description
0
Temperature is
displayed in °F.
0
Temperature is
displayed.
0
12-hour clock format. 1
2
Fan operates
continuously in
Occupied and
Recovery mode. Fan
operates with call for
heating or cooling in
Unoccupied mode.
0
0Time-of-day
contacts.
0
No extended fan
operation after the
call for heat ends.
0
No extended fan
operation after the
call for cool ends.
0
Fan setting key is
operational.
0
Remote sensing not
activated.
0
Temperature
averaging disabled.
0
No lockout.
(Press
Display
1
Temperature is displayed
in °C.
1
Temperature is not
displayed.
24-hour clock format.
0 or 1
0—Fan only operates with
1—Fan operates
1
1—Economizer contacts.
1
Fan operation is extended
90 seconds after the call
for heat ends.
1
Fan operation is extended
90 seconds after the call
for cool ends.
1
Fan setting key is Auto
only.
1
Remote sensing
activated.
1
Temperature averaging
between local sensor and
remote sensor(s)
activated.
1 or 2
1—Lockout all keys on
2—Lockout all keys except
3Lockout all keys except
4
Other Choices
or
key to change)
Description
calls for heating or
cooling in Occupied
and Unoccupied
modes.
continuously in
Occupied mode. Fan
operates with calls for
heating or cooling in
Unoccupied mode.
thermostat except
system and fan
settings, temporary
setpoint, clock and day
adjustments.
set Current Day/Time,
increase
and
decrease
keys.
temporary occupied,
Set Current Day/Time
(for clock, day
adjustments).