A hi-limit thermostat turns off electrical power to the
steam generator if it overheats. To reset this thermo-
stat, allow approximately 45 minutes for the unit to cool
down, remove the black cap, and then press the black
reset button located on the rear of the unit (Figure 7).
If the unit requires continuous resetting, contact your
Roundup authorized service agency.
Hi-Limit Reset Button
Power Cord
Figure 7. Hi-Limit Reset Button (MS-150 shown)
P/N 1010699 Rev. M 12/06

Fault Codes

When the programming parameters for Minutes/
Seconds/SHO/H2O have been inadvertently changed
below or above their limits, the unit displays the "ERR"
fault code. If this code appears, clear these settings
using the procedure below:
1. Turn the unit off.
2. Press and hold the Program and Start/Stop
Cap
3. Turn the unit on while holding the appropriate
4. The display will now register the cycle time.
NOTE: Repeat these steps if the unit still displays
the ERR fault code.
NOTE: It is recommended that the SHO and H2O
settings be adjusted to the recommended settings
shown in the Programming section of this manual.
13
MIRACLE STEAMER
buttons simultaneously (for all units except MS-
150/250 with Mfg. number 9100424, 432, 433
& 439) or Up and Down Arrow buttons for MS-
150/250 with Mfg. number 9100424, 432, 433, &
439 only).
buttons. Release the buttons when the unit stops
beeping,