520/
530 Dealer Knowledge Book
ER-A
A
PLU Unit Price - 1210
* In case the price shift function is allowed, the register prompts to enter a unit price for the following level by
displaying "P2" thru "P6" on the display, and when a unit price of level 6 is entered, the register goes to the
status for programming the following PLU/UPC. When you press the
prices for a PLU/UPC code, prices for the remained levels are kept unchanged.
In case the single price entry is allowed for a PLU/UPC code, the register goes to the status for programming
the following PLU/UPC.
MRS = 000000
Notes:
If a price is entered for a PLU which has been previously set as "Inhibited" or "Open" in
PGM Job #1200, then the type is changed as follows: "Inhibited"
"Open & Preset".
Price-2 – Price-6 are available when SRV Job #971-D File Group 6 is set.
The preset amount will work as the unit price for the "Preset" type and as the HALO
amount for the "Open" type. In the case of the "Open" type, zero preset prevents amount
entry and a 9999.99 preset is the maximum limitation. In the case of the "Preset" type
zero and 9999.99 preset have no special meaning (i.e. zero amount preset is available).
Page 114 of 266
key while programming multiple
Specifications subject to change without notice: Revision date 10/07
"Preset" and "Open"